Programming
Quick MDC
Programming a button for Quick MDC allows two possible uses of the button. The first possible
configuration is the selection of manual MDC in the next field. This allows a single button to enter the
MDC menu using the programmed call type and allow the operator to select the target ID or alias. The
operator may not select another call type.
The second possible configuration is the selection of a programmed alias in the next field. This
configuration allows a single button to send a MDC message of the programmed call type to the
programmed alias immediately upon pressing the button without the intervention of the operator.
N
: In either configuration, the call type selected is not affected by the enabled call types available to
OTE
the operator.
Quick Page
Programming a button for Quick Paging allows two possible uses of the button. The first possible
configuration is the selection of manual paging in the next field. This allows a single button to enter the
paging menu using the programmed page type and allow the operator to select a capcode or alias for the
page. The operator may not select another page type.
The second possible configuration is the selection of a programmed alias in the next field. This
configuration allows a single button to send a page to the programmed alias immediately upon pressing
the button without the intervention of the operator.
N
: In either configuration, the page type selected is not affected by the enabled page types available
OTE
to the operator.
Supervisor via Function Tone
In order to disconnect parallel units from the transmitter at any time, supervisory control via relay may be
required. Upon pressing the button, the assigned relay is engaged, the LED associated with the button
lights and properly connected parallel units are disconnected. The installer must make the proper
connections to the relay control module. A second press of the button reconnects the disconnected
parallel units and the LED associated with the button is extinguished.
: The selected relay is not available for selection in the Relay Outputs menu. Supv. via Relay
N
OTE
cannot be assigned to the
Supervisor via Relay
Select the relay output this button will control. Pressing this button either toggles the status of the relay
output (if Latching is checked) or asserts the relay output for as long as the button is pressed (if
Latching is not checked). If LED is checked, this button's LED indicates the current status of the relay
output (lit if asserted, unlit if not asserted).
Assign a button to tone supervisor control. For supervisor control requiring parallel units to be
physically disconnected, use Relay Control.
Wildcard
Wildcards are used to control the operation of the tone/dc remote adapter or station. Wildcards can be
momentary or push-on/push-off. If latching is not selected, only the first frequency/current must be
entered. This frequency/current is transmitted each time the button is pressed and no LED indication is
provided. If latching is selected, the first and second frequency/current must be entered. The associated
LED is assigned to the button. The first frequency/current is transmitted upon the
button; the second frequency/current is transmitted upon
function of a programmable button.
LOCK
Model L3149B C200 Advanced Desk Set
OFF
press of the button.
50
press of the