General Maintenance Recommendations; Service/Adjustments; Storage; Specifications - Generac Power Systems 7500 Owner's Manual

7500 watt ac generator
Hide thumbs Also See for 7500:
Table of Contents

Advertisement

Generac Portable Products 7500EXL Extended Life Generator
GENERAL MAINTENANCE
RECOMMENDATIONS
The Owner/Operator
is responsible for making sure
that all periodic maintenance tasks are completed on a
timely basis; that all discrepancies
are corrected; and
that the unit is kept clean and properly stored. Never
operate
a damaged
or defective
generator.
Engine Maintenance
See engine manual for instructions
Generator
Maintenance
Generator maintenance consists of keeping the unit
clean and dry Operate and store the unit in a clean
dry environment where it will not be exposed to
excessive dust, dirt, moisture or any corrosive vapors.
Cooling air slots in the generator must not become
clogged with any foreign material.
Check the cleanliness of the generator frequently and
clean when dust, dirt, oil, moisture or other foreign
substances are visible on its exterior surface.
NOTE: Do Not use a garden hose to clean generator.
Water can enter engine fuel system and cause
problems. In addition, if water enters generator
through cooling air slots, some of the water will be
retained in voids and cracks of the rotor and stator
winding insulation. Water and dirt buildup on the
generator internal windings will eventually decrease
the insulation resistance of these windings.
To Clean the Generator
• Use a damp cloth to wipe exterior surfaces clean.
• A soft bristle brush may be used to loosen caked-on
dirt or oil.
• A vacuum cleaner may be used to pick up loose dirt
and debris.
• Low pressure air (not to exceed 25 psi) may be
used to blow away dirt. Inspect cooling air slots and
opening on generator.
SERVICE/ADJUSTMENTS
Refer to engine owner's manual for information
STORAGE
The generator should be started at least once every
seven days and allowed to run at least 30 minutes
If
this cannot be done and you must store the unit for
more than 30 days, use the following guidelines to
prepare it for storage.
• Clean the generator as outlined in "To Clean the
Generator."
• Check that cooling air slots and openings on
generator are open and unobstructed.
• Disconnect the negative battery cable from the
battery.
,_ll
DANGER:
Storage covers can be flammable.
Do Not place a storage cover over a hot
generator. Let the unit cool for a sufficient time
before placing the cover on the unit.
Engine Storage
See engine owner's manual for instructions on how to
properly store the engine.
Other Storage Tips
• Do Not store gasoline from one season to the next.
• Replace your gasoline can if it starts to rust. Rust
and/or dirt in a gasoline can cause problems when
you use that fuel with this unit.
• Store unit in clean and dry area.
SPECIFICATIONS
Rated Maximum Continuous
AC Power Output ...................................
7500 watts (7.5 kW)
Rated Voltage .........................................
120/240 Volts
Rated Maximum AC Current
at 120 Volts .........................................
62.5 Amps
at 240 Volts .........................................
31.2 Amps
Phase .....................................................
1
Rated AC Frequency .............................. 60 Hertz
Number of Rotor Poles ........................... 2
Driven Speed of Rotor ............................ 3600 rpm
i
12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7500exl1019-1

Table of Contents