Operating Automatic Idle Control; Battery Safety; Charging A Battery - Generac Power Systems 7500 Owner's Manual

7500 watt ac generator
Hide thumbs Also See for 7500:
Table of Contents

Advertisement

Generac Portable Products 7 500EXL Extended L ifeGenerator
Operating
Automatic
Idle Control
This switch is designed to greatly improve fuel
economy. When this switch is turned ON, the engine
will only run at its normal high governed engine speed
when an electrical load is connected. When an
electrical load is removed, the engine wilt run at a
reduced speed. With the switch OFF, the engine will
run at the normal high engine speed. Always
have
the switch OFF when starting and stopping the
engine.
Battery Safety
A
DANGER:
Storage batteries give off explosive
hydrogen gas while recharging. An explosive
mixture will remain around the battery for a
long time after it has been charged. The
slightest spark can ignite the hydrogen and
cause an explosion, which can shatter the
battery and cause blindness or other injury.
,_ll
DANGER:
Do Not permit smoking, open
flame, sparks or any other source of heat
around a battery. Wear protective goggles,
rubber apron and rubber gloves when working
around a battery. Battery electrolyte fluid is an
extremely caustic sulfuric acid solution that can
cause severe bums. If spill occurs flush area
with clear water immediately.
Charging
a Battery
Your generator has the capability of recharging a
discharged 12 Volt automotive or utility style storage
battery. Do Not use the unit to charge any 6 Volt
batteries
Do Not use the unit to crank an engine
having a discharged battery
To recharge
12 Volt batteries, proceed as follows:
• Check fluid level in all battery cells If necessary,
add ONLY distilled water to cover separators in
battery cells. Do Not use tap water.
• If the battery is equipped with vent caps, make sure
they are installed and are tight.
• If necessary, clean battery terminals.
• Connect battery charge cable connector plug to
panel receptacle identified by the words
"12-VOLTS D.C.".
• Connect battery charge cable clamp with red handle
to the positive (+) battery terminal (Figure 7).
Red
\
12 VOLT D.C.
RECEPTACLE
Black
+
POS
NEG
• Connect battery charge cable clamp with black
handle to the negative (-) battery terminal,
(Figure 7).
• Start engine. Let the engine run while battery
recharges.
• When battery has charged, shut down engine
NOTE: Use an automotive hydrometer to test battery
state of charge and condition. Follow the hydrometer
manufacturer's
instructions carefully. Generally, a
battery is considered to be at 100% state of charge
when specific gravity of its fluid (as measured by
hydrometer) is 1.260 or higher.
/
8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7500exl1019-1

Table of Contents