Air Conditioning With Installation; Electrical Connection (U.k. Only) - DeLonghi Pinguino F110 Instructions Manual

Table of Contents

Advertisement

F110
4-04-2003
11:10

AIR CONDITIONING WITH INSTALLATION

For more efficient use Pinguino can also be
semi-permanently installed
30 cm
To install, proceed as follows:
• Make a hole in a outside wall or through
the pane of a window. Check the height
and dimensions given in figure E
in a window
in the
pane
wood sill of
a window
E
E L E C T R I C A L
A)
If your appliance comes fitted with a plug, it will incorporate
a 13 Amp fuse. If it does not fit your socket, the plug should
be cut off from the mains lead, and an appropriate plug
fitted, as below.
WARNING: Very carefully dispose of the cut off plug after
removing the fuse: do not insert in a 13 Amp socket
elsewhere in the house as this could cause a shock hazard.
With alternative plugs not incorporating a fuse, the circuit
must be protected by a 15 Amp fuse.
WARNING - THIS APPLIANCE MUST BE EARTHED
The wires in the mains lead are coloured in accordance with the
following code:
Green and yellow:
Blue:
Brown:
Pagina 15
S e t t i n g u p
30 cm
D
in the wall: for opti-
mum results, insulate
the sec-tion of the
wall with suitable
insu-lating material.
C O N N E C T I O N
IMPORTANT
Earth
Neutral
Live
14
• Fit the flange
supplied to the hole.
15
• Fix the hose
to the coupling on the
back of the unit (figure A).
• Attach the end of the hose
14
ge
as shown in the figure F.
15
When the hose
is not attached, close the
hole with the bung on the flange
NOTE:
When the unit is installed semi-permanently,
we recommend leaving a door slightly open
(1 cm is enough) to ensure an adequate
exchange of air.
( U . K .
If the plug is a moulded-on type, the fuse cover must be re-
fitted when changing the fuse using a 13 Amp Asta
approved fuse to BS 1362. In the event of losing the fuse
cover, the plug must NOT be used until a replacement fuse
cover can be obtained from your nearest electrical dealer.
The colour of the correct replacement fuse cover is that as
marked on the base of the plug.
B)
If your appliance is not fitted with a plug, please follow the
instructions provided below:
As the colours of the wires in the mains lead may not correspond
with the coloured markings identifying the terminals in your plug,
proceed as follows: The green and yellow wire must be
connected to the terminal in the plug marked with the letter E or
the earth symbol
or coloured green or green and yellow.
The blue wire must be connected to the terminal marked with the
letter N or coloured black. The brown wire must be connected to
the terminal marked with the letter L or coloured red.
15
to the flan-
F
MAX115 cm
MIN 50 cm
14
.
O N L Y )

Hide quick links: