Important Safe-guards
• This appliance has been manufactured to cool and de-humidify domestic environments and
should not be used for other purposes.
• It is dangerous to alter or modify the unit's characteristics in any way.
• The appliance must be installed in conformity with the relevant national legislation.
• Should repairs be necessary, contact the nearest authorised Repair Service Centre. Unautho-
rised servicing can be dangerous.
• This appliance is to be used by adults only; keep children away from it.
• The appliance is not intended for use by young children or infirm persons without supervision.
• Young children should be supervised to ensure that they do not play with the appliance.
• Always ground the appliance. Have the electrical system checked by a qualified electrician.
• Avoid using extension leads with the unit.
• Before cleaning or maintenance operations, always unplug the unit from the socket.
• Do not pull on or place strain on the power cable when moving the appliance.
• The appliance should not be installed where the atmosphere may contain combustible gases,
oil or sulphur, or near heat sources.
• If the appliance is utilised in areas where there is no ventilation of air, it is necessary to take pre-
cautions to avoid that the refrigerant gases that may leak from the appliance do not remain
in the room, thereby causing a fire hazard.
• Do not rest hot or heavy objects onto the appliance.
• Clean the anti-bacterial filters at least once a week.
• Avoid using heaters near the unit.
• The unit should be transported in a vertical position. If this is not possible secure the unit at an
angle, do not lie horizontally. Before transporting the unit drain the condensation collecting-
tray and tank. Avoid transportation, wait at least 1 hour before switching on the unit.
• The packaging materials can be recycled. You are therefore recommended to place them in
the special containers for differentiated waste collection.
• Keep the unit at least 50 cm away from inflammable substances (alcohol etc) or pressurised
containers (eg. aerosol cans).
• The appliance must be used only as indicated in this manual. These instructions are not inten-
ded to cover as many as possible conditions and situations which may arise. As with all hou-
sehold appliances installation, operation and conservation should be carried out prudently
and following common sense.
• In the case that the power cable becomes damaged, this must be substituted only by spe-
cialised personnel authorised by the manufacturer.
• Do not cover this appliance with bags when is not in use.
• Unventilated area where the appilance using flammable refrigerants is installed shall be so
constructed that any leaked refrigerants will not stagnate so as to cause a fire or an explosion
hazard caussed by igniting stagnant refrigerants from other source such as electric heater,
stove and similar home applications.
This appliance contains substances which, if released into the atmosphere, would damage the
ozone layer. Care should therefore be taken not to perforate the refrigerant circuit. At the end of
its working life, deliver the air conditioning unit to a special collection centre.
4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FX160ECO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DeLonghi FX160ECO

  • Page 1 19-06-2003 9:09 Pagina 4 Important Safe-guards • This appliance has been manufactured to cool and de-humidify domestic environments and should not be used for other purposes. • It is dangerous to alter or modify the unit's characteristics in any way. •...
  • Page 2 In suitcase models (Super- Pinguino), the circuit is cooled using the air outsi- For more details, contact or visit our Internet site www.delonghi.com...
  • Page 3: Description Of The Appliance

    19-06-2003 9:09 Pagina 6 Description of the appliance DESCRIPTION MODEL FX160ECO 1) Air discharge grill 2) Control Panel 3) Wheels 4) Handles 5) Housing for air exhaust hose 6) Cord winder 7) Air intake grill 8) Rating plate 9) Water collection tank...
  • Page 4 19-06-2003 9:09 Pagina 7 S e t t i n g u p When positioning the appliance, always ensure that nothing obstructs the intake and discharge of • If you have a double window, use the AIR CONDITIONING WITHOUT PERMANENT suckers (16) supplied to keep the panes from INSTALLATION opening wide (figure 3).
  • Page 5 19-06-2003 9:09 Pagina 8 S e t t i n g u p • Fit the flange (13) supplied to the hole. AIR CONDITIONING WITH SEMI-PERMA- • Fix the hose (14) in the housing at the rear NENT INSTALLATION of the appliance (fig 1) If desired, Pinguino can also be installed on a •...
  • Page 6: Description Of The Control Panel

    19-06-2003 9:09 Pagina 9 Description of the control panel THE DISPLAY A. ON/OFF Button B. Function Button Air-conditioning, dehumidifying, ventila- tion C. Air-conditioning indicator D. dehumidifying indicator E. Purification indicator F. Increase temperature button / increase operating time button G. Decrease temperature button / Decrease operating time button H.
  • Page 7: Switching The Appliance On

    19-06-2003 9:09 Pagina 10 O p e r a t i o n SWITCHING THE APPLIANCE ON Connect the appliance to the mains supply. On the display two lines will appear indicating Stand-by mode Press the ON/OFF button (A) and then the MODE button until the relevant function indicator appears viz.: Indicator C : air-conditioning...
  • Page 8: Programming The Timer

    19-06-2003 9:09 Pagina 11 O p e r a t i o n VENTILATION/PURIFICATION This is ideal for dusty or polluted areas; in effect, the appliance “Silent” recycles and purifies the air using the dust filters and 3M Filtrete™ speed electrostatic filters fitted.
  • Page 9: Self-Diagnosis

    19-06-2003 9:09 Pagina 12 O p e r a t i o n THIS UNIT EMPLOYS AN EXCLUSIVE CON- MAKE SURE THE TANK IS PUT BACK COR- DENSATION RECYCLING SYSTEM TO DISPO- RECTLY OTHERWISE IN THE DISPLAY WILL SE OF EXCESS MOISTURE. IN NORMAL REMAIN CONDITIONS, CONDENSATION IS DISPO- SED OF AUTOMATICALLY.
  • Page 10 19-06-2003 9:09 Pagina 13 R e c o m m e n d a t i o n s • Do not install the heater in humid environ- Follow these recommendations to achieve maximum efficiency from your air conditio- ments. ning unit: •...
  • Page 11: Cleaning The Air Filters

    19-06-2003 9:09 Pagina 14 C l e a n i n g Before cleaning or maintenance, switch off the appliance by pressing the ON/OFF button (A) and always unplug it from the mains supply. Dust filter CLEANING THE EXTERNAL UNIT We recommend cleaning the appliance with intake grille a slightly damp cloth.
  • Page 12: Troubleshooting

    19-06-2003 9:09 Pagina 15 Troubleshooting PROBLEM CAUSES REMEDY The air-conditioner • the power is off • the appliance is not plugged in • Plug it in does not work The air-conditioner • The exhaust hose is twisted • Position exhaust hose correctly works only for a •...
  • Page 13: Technical Specification

    19-06-2003 9:09 Pagina 16 Technical specification TECHNICAL SPECIFICATION OPERATING LIMITS Power supply see rating plate Max. absorbed power Room temperature 21 - 35°C in air conditioning “ 69,8 - 95°F Max. absorbed power when dehumidifying “ Refrigerating capacity* “ Number of fan speeds 2 + silent Max.
  • Page 14 19-06-2003 9:09 Pagina 17 L o n g h i S . p . A . V i a S e i t z , 3 1 1 0 0 T r e v i s o I t a l i a t e l .

Table of Contents