Download Print this page

System Specifications; Amplifier Section - Genelec 8040A Operating Manual

8000 series
Hide thumbs Also See for 8040A:

Advertisement

8040A and 8050A Operating Manual

SySTeM SPecIFIcATIoNS

Lower cut-off frequency, -3 dB
Upper cut-off frequency, -3 dB
Free field frequency response of
system (± 2.0 dB)
Maximum short term sine wave
acoustic output on axis in half
space, averaged from 100 Hz to
3 kHz
@ 1 m
@ 0.5 m
Maximum long term RMS acoustic
output in same conditions with IEC
weighted noise (limited by driver
unit protection circuit) @ 1 m
Maximum peak acoustic output
per pair above console top, @ 1
m from the engineer with music
material
Self generated noise level in free
field @ 1m on axis (A-weighted)
Harmonic distortion at 90 dB SPL
@ 1m on axis
Freq. 50 to 100 Hz
> 100 Hz
Drivers:
Bass
Treble
Both drivers are
magnetically shielded
Weight:
Dimensions:
Height (without table support
Height (including table support)
Width
Depth
Genelec Document D0003R001a Copyright Genelec Oy 2.2005-. All data subject to change without prior notice
8040A
8050A
≤ 45 Hz
≤ 35 Hz
≥ 21 kHz
≥ 21 kHz
48 Hz - 20 kHz
38 Hz - 20 kHz
≥ 105 dB SPL
≥ 110 dB SPL
≥ 111 dB SPL
≥ 116 dB SPL
≥ 99 dB SPL
≥ 101 dB SPL
≥ 115 dB SPL
≥ 120 dB SPL
≤ 10 dB
≤ 10 dB
< 2 %
< 2 %
< 0.5 %
< 0.5 %
165 mm (6 1/2")
205 mm (8")
19 mm (3/4")
25 mm (1")
metal dome
metal dome
8.6 kg (18.9 lbs)
12.7 kg (28 lbs)
350 mm (13 13/16")
433 mm (17 1/16")
365 mm (14 3/8")
452 mm (17 13/16")
237 mm (9 3/8")
286 mm (11 1/4")
223 mm (8 13/16")
278 mm (10 15/16")
International enquiries:
Genelec, Olvitie 5
FIN-74100, Iisalmi, Finland
Phone +358 17 83881
Fax +358 17 812 267
Email genelec@genelec.com
croSSover SecTIoN
Input connector XLR female
Input impedance
Input level for maximum short term
output of 100 dB SPL @ 1m:
Crossover frequency, Bass/Treble
Treble tilt control operating range in
2 dB steps
Desktop low frequency control
operating range
Bass roll-off control operating
range in 2 dB steps
Bass tilt control operating range in
2 dB steps

AMPLIFIer SecTIoN

Bass amplifier short
term output power
Treble amplifier short
term output power
Long term output power is limited
by driver unit protection circuitry
Amplifier system distortion
at nominal output
THD
SMPTE-IM
CCIF-IM
DIM 100
Signal to Noise ratio, referred to
full output
Bass
Treble
Mains voltage
Voltage operating range
Power consumption
Idle
Full output
In the U.S. please contact:
In China please contact:
Genelec, Inc., 7 Tech Circle
Beijing Genelec Audio Co. Ltd.
Natick, MA 01760, USA
Jianwai SOHO, Tower 12, Room 2306
Phone +1 508 652 0900
39 East 3rd Ring Road
Fax +1 508 652 0909
Chaoyang District, Beijing 100022, China
Email genelec.usa@genelec.com
Phone +86 0 5869 7915
Fax +86 10 5869 7914
8040A
8050A
Pin 1 gnd, pin 2 +, pin 3 -
10 kOhm balanced
Adjustable from +6 to -6 dBu
3.0 kHz
1.8 kHz
From +2 to -4 dB &
From +2 to -4 dB &
MUTE @ 15 kHz
MUTE @ 15 kHz
-4 dB @ 160 Hz
-4 dB @ 160 Hz
From 0 to -6 dB
From 0 to -6 dB
@ 45 Hz
@ 35 Hz
From 0 to -6 dB @
From 0 to -6 dB @
100 Hz & MUTE
100 Hz & MUTE
The 'CAL' position is with all tone controls
set to 'off' and the input sensitivity control
to maximum (fully clockwise)
8040A
8050A
90 W (8 Ohm load)
150 W (6 Ohm load)
90 W (8 Ohm load)
120 W (8 Ohm load)
≤ 0.05 %
≤ 0.05 %
≤ 0.05 %
≤ 0.05 %
≤ 0.05 %
≤ 0.05 %
≤ 0.05 %
≤ 0.05 %
≥ 100 dB
≥ 100 dB
≥ 100 dB
≥ 100 dB
100, 120, 220 or 230 V
according to region
±10 %
±10 %
10 VA
10 VA
110 VA
170 VA
www.genelec.com
In Sweden please contact:
Genelec Sverige
Box 5521, S-141 05 Huddinge
Phone +46 8 449 5220
Fax +46 8 708 7071
Email info@genelec.com