20 www.electrolux.com
Installing the shelf support
To install the shelf support follow the pro-
cedure in the opposite order.
12.3 Steam generation system
CAUTION!
Dry the steam generator after
each use. Remove the water with
the sponge.
Remove the limescale with water
and vinegar.
CAUTION!
Chemical de-scaling agents can
cause damage to the enamel. Fol-
low the instructions of the manu-
facturer.
Cleaning the water drawer and the
steam generator:
1.
Put the water and vinegar mixture
(approximately 250 ml) through the
water drawer into the steam genera-
tor. Wait for approximately 10 mi-
nutes.
2.
Remove the water and vinegar with
the sponge.
3.
Put clean water (100 - 200 ml) into
the water drawer to flush the steam
generation system.
2.
Lightly move the support on the front
catch inwards.
3.
Pull the support out of the rear catch.
4.
Remove the water from the steam
generator with the sponge and rub it
dry.
5.
Keep the door open to let the appli-
ance dry fully.
12.4 Lamp
WARNING!
There is a risk of electrical shock.
The lamp and the lamp glass cov-
er can be hot.
Before you change the lamp:
• Deactivate the appliance.
• Remove the fuses from the fuse box or
deactivate the circuit breaker.
CAUTION!
Put a cloth on the bottom of the
interior of the appliance. It pre-
vents damage to the lamp glass
cover and the cavity.
Always use the same lamp type.
Replacing the lamp at the cavity
ceiling:
1.
Turn the lamp glass cover counter-
clockwise to remove it.
2.
Remove the metal ring and clean the
glass cover.
3.
Replace the lamp with a suitable 300
°C heat-resistant lamp.