S U G G E S T E D E N T R A P M E N T P R O T E C T I O N D E V I C E L O C A T I O N S
SWING GATE SYSTEM
Shadow loop should be positioned in direction
of gate travel. Pull-to-open illustrated.
The shadow loop input is only active when the
gate is in the fully open or fully closed positions.
DUAL SWING GATE SYSTEM
STREET
Control
Box
Shadow loop should be positioned in direction
of gate travel. Pull-to-open illustrated.
The shadow loop input is only active when the
gate is in the fully open or fully closed positions.
Telephone
Entry System
STREET
Photo Eye for
Close Cycle
Telephone
Entry System
Gate 1
Photo Eye for
Close Cycle
Photo Eye for
Open Cycle
COMPLEX
PARKING LOT
Gate 2
Junction
Box
Extension Cable
Photo Eye for
Open Cycle
COMPLEX
PARKING LOT
6
Run Twisted Wire
from Loop to Operator
Seal Loops
1-1/2"
(37 mm)
Loop Wire Layer
1/4" (6 mm) or larger
depending on Loop
Wire size
OR
Run Twisted Wire
from Loop to Operator
Seal Loops
1-1/2"
(37 mm)
Loop Wire Layer
1/4" (6 mm) or larger
depending on Loop
Wire size