System Unit
Dimensions (H x W x D)
(with bezel)
Weight
(approximate)
Power Specifications
System Inlet Temperature
(Single-width type)
DA - 14409 North America — Version 16 — December 13, 2013
HP ProLiant WS460c Gen8 Workstation Blade
Single-width: 7.11 x 2.18 x 20.37 in (18.07 x 5.54 x 51.76 cm)
Double-width: 7.11 x 4.46 x 20.37 in (18.07 x 11.08 x 51.76 cm)
(Single-width type)
Maximum: all processors,
16 DIMMs, hard drives,
mezzanine cards, and two
flash cache batteries
installed)
Minimum: one processor
and 2 DIMMs installed
(Double-width type)
Maximum: all processors,
16 DIMMs, hard drives,
mezzanine cards, and two
flash cache batteries
installed), dual MultiGPU
Carrier with eight Q1000M
Minimum: one processor
and 2 DIMMs installed,
expansion blade slot 1,2
enabled, both slots vacant
For power specifications including input requirements, BTU rating, and power
supply output, please see the:
HP BladeSystem c3000 Enclosure QuickSpecs:
http://h18000.www1.hp.com/products/quickspecs/12790_na/
12790_na.html
HP BladeSystem c7000 Enclosure QuickSpecs:
http://h18000.www1.hp.com/products/quickspecs/12810_na/
12810_na.html
To review typical system power ratings use the HP Power Advisor which is
available via the online tool located at:
http://www.hp.com/go/bladesystem/powercalculator
Operating
Non-operating
14.00 lb (6.33 kg)
10.50 lb (4.75 kg)
22.25 lb (10.09 kg)
15.69 lb (7.12 kg)
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m (1.8°F
per every 1000 ft) above sea level to a maximum
of 3050 m (10,000 ft), no direct sustained
sunlight.
Maximum rate of change is 10°C/hr (18°F/hr). The
upper limit may be limited by the type and
number of options installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).