Electrolux Premier DSO51DF Instruction Booklet page 7

Mixed fuel cooker
Hide thumbs Also See for Premier DSO51DF:
Table of Contents

Advertisement

The cooker should not be installed in a bed
3
sitting room with a volume of less than 20m
, if it
3
is installed in a room of volume less 5m
an air
2
vent of effective area of 110cm
is required; if it is
3
installed in a room of volume between 5m
and
3
2
10m
, an air vent of effective area 50cm
is
3
required, while if the volume exceeds 11m
no air
vent is required. However, if the room has a door,
which opens directly to the outside, no air vent is
3
required even when the volume is between 5m
3
and 11m
.
If there are other fuel burning appliances in the
same room, B.S. 5440: Part. 2: Current Editions
should be consulted to determine the requisite air
vent requirements.
Location
The cooker may be located in a kitchen, a
kitchen/diner or bed sitting room but not in a
bathroom, shower room or garage.
For information regarding the fitting of flexible
supply pipes, the highest temperature at the rear
of this cooker which may come into contact with
the supply pipe is 70°C above ambient.
When the appliance has been installed there
must be enough space for the hotplate lid (if
there is) to open fully.
Levelling
The appliance is provided with adjustable small
feet placed in the back and front corners of the
base.
By adjusting the small feet it is possible to
change the height of the appliance so as to
ensure a better levelling with other surfaces and
an even distribution of the liquids contained in
pots and pans.