Download Print this page

Specifications - Furman ELITE-20 PF i Owner's Manual

Ultra-linear filtering ac power conditioner

Advertisement

Available languages

Available languages

Specifications

AC Current Capacity:
Input - 20 Amp capacity required
Output - 16-20 Amps RMS (maximum, all outlets combined - continuous)
Linear Noise Attenuation:
Transverse (Differential) Mode:
>40 dB from 5 kHz. - 100 kHz.
>80 dB from 100 Khz. – 1GHz.
(Linear attenuation curve from 0.05 – 100 ohms line impedance)
Transient Voltage Surge Suppression:
120 VAC: Series Multi-Stage Protection - Non-Sacrificial with Zero Ground Contamination.
(188 V peak clamping @ 6000V - 3000A input)
Extreme Voltage Shutdown (>140 VAC)
Telco
Cable / Satellite (less than .1dB insertion loss)
Power Consumption:
12 Watts for display and control circuits independent of actual load.
Outlets:
1 (Ultra-Linearly filtered outlet - front panel)
8 (Ultra-Linearly filtered outlets with additional ultrasonic filtering for either video or audio components,
4 with 12V triggering)
4 (Power Factor Technology amplifier outlets – 4.5 amps RMS reserve - resistive load - over 55 amps peak
charge, 2 with 5 second delay via 12V triggering)
Dimensions:
4" H x 17" W x 14.75" D (Standard 2 RU height without feet)
Weight:
18 lbs.
11

Advertisement

loading