Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
defective product in the manner and for the period provided above. Furman shall not have any other obligation with respect to the
products or any part thereof, whether based on contract, tort, strict liability or otherwise. Under no circumstances, whether based on
this Limited Warranty or otherwise, shall Furman be liable for incidental, special, or consequential damages. This Limited Warranty
states the entire obligation of Furman with respect to the product. If any part of this Limited Warranty is determined to be void or il-
legal, the remainder shall remain in full force and effect.

SPECIFICATIONS

CURRENT RATING:
10 amps
OPERATING VOLTAGE:
180 to 274 VAC
OVER VOLTAGE SHUTDOWN:
275 VAC typically
SPIKE PROTECTION MODES:
Line to neutral, zero ground leakage
SPIKE CLAMPING VOLTAGE:
376 VAC peak @ 3,000 Amps, 266 VAC RMS
RESPONSE TIME:
1 nanosecond
MAXIMUM SURGE CURRENT:
6,500 amps
NOISE ATTENUATION:
10 dB @ 10 kHz, 40 dB @ 100 kHz, 50 dB @ 500 kHz
Linear attenuation curve from 0.05 - 100 Ohms line impedance
DIMENSIONS:
44.45mm H x 482.6mm W x 266.7mm D.
WEIGHT:
5 kg
CONSTRUCTION:
Steel chassis, 3mm brushed and black anodized aluminum front panel; glass epoxy printed circuit boards
POWER CONSUMPTION:
25 VA
SAFETY AGENCY LISTING:
CE
8
PL-PLUS C E OWNER'S MANUAL

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents