3. S
ETUP

AC Power

Fuse
Replacement
(Power Linking)
Page 6 of 16
The 4BAR™ Flex has an auto-ranging power supply and it can work with an input
voltage range of 100~240 VAC, 50/60 Hz.
To determine the product's power requirements (circuit breaker, power outlet, and
wiring), use the current value listed on the label affixed to the product's back panel, or
refer to the product's
Technical
product's average current draw under normal conditions.
Always connect the product to a protected circuit (circuit breaker or fuse). Make
sure the product has an appropriate electrical ground to avoid the risk of
electrocution or fire.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even
if the rheostat or dimmer channel serves only as a 0 to 100% switch.
Follow the instructions below to change the power linking fuse, if necessary.
Disconnect the product from the power outlet before replacing the fuse.
1.
Disconnect the product from power.
2.
With a flat-head screwdriver, unscrew the fuse holder
cap from the housing.
3.
Remove the blown fuse.
4.
Replace with a fuse of the exact same type and rating.
5.
Screw the fuse holder cap back in place and
reconnect power.
Always replace a blown fuse with another of the same type and rating.