INSTALLATION INSTRUCTIONS

Installation Checklist

Location
• Is the water heater located within the venting requirements and close to the main use of hot water? . . . . . .
• Is the water heater protected from freezing temperatures? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• Has a drain pan been installed and piped to a free-flowing drain? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• Is the gas control valve accessible for servicing? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• Have clearances from combustible materials been observed? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Combustion and Ventilation Air Supply
• Is the area around the water heater clean and properly ventilated? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• Is the fresh air supply free of corrosive elements and flammable vapours? . . . . . . . . . . . . . . . . . . . . . . . . . .
• Does the water heater have access to enough fresh combustion air? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• Have the fresh air openings been sized correctly and
has consideration been given to the blocking effect of louvers and grilles? . . . . . . . . . . . . . . . . . . . . . . . . . .
Venting
• Is the flue baffle installed in the flue tube?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• Has the water heater been vented separately from all other appliances?. . . . . . . . . . . . . . . . . . . . . . . . . . . .
• Have only PVC or CPVC pipe and fittings been used to assemble the vent piping? . . . . . . . . . . . . . . . . . . .
• Have all horizontal runs of vent pipe been installed with a minimum rise of
/
inch per foot (21 mm/m) of run? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
4
• Has all the vent piping been secured with the appropriate primer and solvent-based cement? . . . . . . . . . . .
• Has the venting been supported at the proper intervals? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• Have precautions been taken against condensation flowing into the power venter? . . . . . . . . . . . . . . . . . . .
Water Piping
• Is the dip-tube installed in the cold water inlet? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• Has a temperature and pressure-relief valve been installed? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• Does this valve have a discharge line installed and is it piped to a free-flowing drain? . . . . . . . . . . . . . . . . .
• Have all the plumbing connections been properly installed and are they leak-free?. . . . . . . . . . . . . . . . . . . .
• Is the water heater full of water? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Gas Connections
• Is the gas supplied to the water heater the same type as indicated on the water heater rating plate? . . . . .
• Has the gas line been installed with a manual shut-off valve, union and drip leg? . . . . . . . . . . . . . . . . . . . . .
• Is the gas piping large enough and made of an approved material?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• Have all connections been made with an approved joint compound?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• Has the gas piping been tested for leaks with a soap and water solution?. . . . . . . . . . . . . . . . . . . . . . . . . . .
Wiring
• Has the wiring been properly installed? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• Have the electrical connections been checked and are they secure?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• Is the water heater electrically grounded? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
• Does the 120V wall receptacle have the proper polarity? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .