Abit FATAL1TY AN9 32X User Manual page 42

Motherboard amd socket am2
Hide thumbs Also See for FATAL1TY AN9 32X:
Table of Contents

Advertisement

Voltage Monitoring
Click <Enter> key to enter its submenu:
(*)CPU Core Voltage
(*)DDR2 Voltage
(*)DDR2 VTT Voltage
(*)HyperTransport Voltage
(*)NB Voltage
(*)CPU VDDA 2.5V Voltage
(*)SB Voltage
(*)ATX +12V (24-Pin Connector)
(*)ATX +12V (4-Pin Connector)
(*)ATX +5V
(*)ATX +3.3V
(*)ATX 5VSB
↓↑→←:Move Enter:Select +/-/PU/PD:Value
All Voltages
These items display the voltage of each element.
-
Shutdown Enable
Use <Space> key to enable system shutdown function. If the voltage of corresponding element
is higher/lower than the high/low limit, the system will automatically shutdown.
-
Beep Enable
Use <Space> key to enable warning beeps function. If the voltage of corresponding element is
higher/lower than the high/low limit, warning beeps will sound.
-
High/Low Limit
These items set the high and low voltage limit.
※ The value of high limit must be set above the one of low limit.
3-6
µGuru Utility V1.00C
ABIT EQ
Voltage Monitoring
Reading
Shutdown
Enable
1.40 V (*)
1.80 V ( )
0.90 V ( )
1.20 V ( )
1.20 V ( )
2.50 V ( )
1.50 V ( )
12.00 V ( )
12.00 V ( )
5.00 V ( )
3.30 V ( )
5.00 V ( )
Beep
High
Enable
Limit
(*)
1.60 V
(*)
2.20 V
(*)
1.10 V
(*)
1.45 V
(*)
1.45 V
(*)
3.00 V
(*)
1.00 V
(*)
14.40 V
(*)
14.40 V
(*)
6.00 V
(*)
3.95 V
(*)
6.00 V
F10:Save ESC:Exit
Low
Limit
0 V
1.50 V
0.75 V
0.95 V
0.95 V
2.00 V
1.20 V
9.60 V
9.60 V
4.00 V
2.65 V
4.00 V

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents