Power Connection Kits
230/208-Volt Line Cord Connection Units
Electric
Line Cord
Heat
Kit
BTUH
RAK15
8600/7100
RAK20
11700/9600
RAK0
17100/1900
Electric Heat Amps include electric heater and fan motor current draw.
Each Line Cord Kit has an integral Leakage Current Detection and Interruption (LCDI) or Arc Fault
Current Interrupter (AFCI) device as required by National Electrical Code (NEC) and Underwriters
Laboratories (UL) for units manufactured after August 1, 2004.
265-Volt Sub-Base and Direct Connected Units
Power
Sub-Base
Connection Kit
RAK204E15
RAK5172
RAK204E20
RAK5202
RAK204E0
RAK502
Electric Heat Amps include electric heater and fan motor current draw.
265-volt units are to be permanently connected in compliance with National Electrical Code and local codes and have a factory-installed junction box on the chassis.
Each 265-volt sub-base kit consists of sub-base with appropriate receptacle for minimum circuit amperage, chaseway to route power connector from sub-base to chassis
and wiring to connect sub-base to building wiring.
265-Volt Power Connection Kit must be ordered separately.
Important

Essential Elements Ordering Overview

20/208-volt line cord connected units — order line cord kit
20/208-volt sub-base connected units — order sub-base and junction box
265-volt units — order sub-base and power connection kit
Zoneline
Chassis Nomenclature
®
The Zoneline chassis is identified by a model number defining the type of unit, cooling capacity, electrical information and
optional features included on the unit. When specifying or ordering the Zoneline chassis, the use of this nomenclature will
assure receiving the correct unit.
EXAMPLE
A
Z
5
8
H
Zoneline
Chassis series
packaged
29= deluxe line cool/
terminal
electric heat
9=deluxe line heat pump
chassis
58= premium line
heat pump
Unit type
E= cooling with electric
resistance heat
H= heat pump with electric
resistance heat
Electric
Electric
Min. Circuit
Heater
Heat
Protection
Watts
Amps
(Amps)
2550/2090
11.6/10.6
450/2820
15.5/14.1
5000/4090
22./20.
Direct
Connection Kit
RAK5157
RAK5207
RAK507
1
2
D
A
Nominal cooling capacity
Universal
power connection
07=7,000 BTUH cooling
09=9,000 BTUH cooling
12=12,000 BTUH cooling
Special Features
15=15,000 BTUH cooling
B=base unit
C=corrosion treated
Voltage/Phase/
D= internal
Frequency
condensate
removal (ICR)
D= 20/208-Volt,
system (heat
single-phase, 60 Hz
pump models
E= 265-Volt, single-phase,
only) (not for
60 Hz
coastal areas)
P= Dry Air 25 (2800
Series only)
230/208-Volt Sub-Base and Direct Connected Units
Direct
Sub-Base
Connection
Kit
15
RAK204D15P
RAK4157
20
RAK204D20P
RAK4207
0
RAK204D0P
RAK407
Electric Heat Amps include electric heater and fan motor current draw.
Units connected through sub-base do not require a LCDI or AFCI device since they are not
considered to be line-cord connected. Each 20/208-volt sub-base kit consists of sub-base with
appropriate receptacle for minimum circuit amperage, chaseway to route power connector from
sub-base to chassis, wiring to connect sub-base to building wiring and a short line cord with 9-pin
connector to connect to chassis and plug into receptacle in sub-base.
Short sub-base line cord may not be used without sub-base.
Junction box for 20/208-volt chassis must be purchased separately.
RAK4002A for 2900 and 900 series units RAK4002B for 5800 series units.
Electric Heat
Electric Heater
BTUH
Watts
8600
2550
11700
450
17000
5000
D
Electric
Electric
Electric
Heat
Heater
Heat
BTUH
Watts
Amps
8600/7100
2550/2090
11.6/10.6
11700/9600
450/2820
15.5/14.1
170100/1900 5000/4090
22./20.
Electric Heat
Min. Circuit Protection
Amps
9.6
1.0
18.9
ge.com
Min. Circuit
Protection
(Amps)
15
20
0
(Amps)
15
20
0