Features and Benefits
Easy Clean Air Discharge Area
2900 and 3900 Series units have an out-of-sight vertical
protective screen over the indoor fan. This allows easy
cleaning of air discharge area by simply removing room
front and wiping clean.
There is no screen directly below discharge louver to trap
unsightly dirt and debris where it may be seen by room
occupant.
Concealed Manual
Vent Control
The -position manual vent
door control may be closed,
partially open or fully open.
Unit
7000
9000
12000
15000
CFM ratings at 20 volts and 265 volts.
Greater amounts of air will be introduced if the room has an
exhaust fan.
An open vent door brings unconditioned outdoor air into the
room, increasing heating and cooling costs.
Positive vent door closure prevents accidental opening and
unwanted air infiltration.
Up-Front Air Filters
Two interchangeable
up-front filters, easy
to remove and reinstall,
may be cleaned without
opening or removing
the room front.
Clean filters by brushing,
vacuuming or back-
flushing under faucet
or shower head.
Vent CFM High Speed
Full Open
Partial Open
50
40
70
45
75
45
75
45
Corrosion Protection (Optional)
2900 and 900 Series units may be ordered with special
protection to better withstand damage from salt air and
salt water in seacoast areas.
Corrosion protection is standard on the 5800 Series and
on Dry Air 25 models.
Heat Pump units with ICR are not available with corrosion
protection and should not be installed in seacoast or
corrosive environments.
Units installed in corrosive areas should be examined and
cleaned more frequently than normal installations.
Internal Condensate Removal (ICR)
See page 4 for a discussion of the Internal Condensate
Removal system available on 900 and 5800 Series heat pumps.
Enhanced Dehumidification
Moisture removal is an important function of an air
conditioner. People are more comfortable at higher
temperatures when the humidity level is relatively low.
Air conditioners operate with less energy consumption
when the room temperatures are set higher.
The GE Zoneline
®
2900 Series with the Dry Air 25 heat pipe
application removes 25% more moisture than the base
2900 Series unit.
The GE Zoneline Dry Air 25 chassis is the only PTAC available
with the application of the patented Dinh
Heat Pipe under license from Heat Pipe Technology, Inc.
Customers who are using the Dry Air 25 report a fresher-
smelling room as a result of the lower humidity levels, as
well as lower operating costs.
Locking Door Kit
RAK8023 — A door with a lock that replaces the standard
control cover door to prevent unauthorized changing of
control setting is offered as an accessory.