Weber Platinum II 3200 NG Owner's Manual page 16

Platinum 3200 series natural gas barbecue
Hide thumbs Also See for Platinum II 3200 NG:
Table of Contents

Advertisement

Step 14
Install manifold bracket
You will need: manifold bracket
Hook the bracket onto the manifold at the center burner
valve. Figure 15. Place your hand underneath the bracket.
Lift the bracket, manifold and cooking box slightly as a unit
and hook onto the frame brace.
Figure 15
Step 15
Check for gas leaks
Do not use an open flame to check for gas
leaks. Be sure there are no sparks or open
flames in the area while you check for
leaks. This will result in a fire or explosion
which can cause serious bodily injury or
death and damage to property.
WARNING: You should check for gas leaks every
time you disconnect and reconnect a gas fitting.
Note - All factory made connections have been thoroughly
checked for gas leaks. The burners have been flame
tested. As a safety precaution you should recheck all
fittings for leaks before using your Weber Gas Barbecue.
Shipping and handling may have loosened or damaged a
gas fitting.
Manifold bracket
Frame brace
DANGER
WARNING: Perform these leak checks even if your
barbecue was dealer or store assembled.
You will need: a soap and water solution and a rag or
brush to apply it.
Note - Since some leaks test solutions, including soap
and water, may be slightly corrosive, all connections
should be rinsed with water after checking for leaks.
Make sure side burner is OFF. Remove valve control knob
and screws. Remove porcelain top. Figure 16.
To perform leak checks: Slide back the collar of the quick
disconnect. Push male fitting of the hose into the quick
disconnect, and maintain pressure. Figure 17 (a). Slide
the collar closed. Figure 17 (b). If it does not engage or
lock, repeat procedure. Gas will not flow unless the quick
disconnect is properly engaged.
Turn on gas supply.
(a)
To barbecue
Male fitting
WARNING: Do not ignite burners while leak checking.
Check for leaks by wetting the connections with the soap
and water solution and watching for bubbles. If bubbles
form or if a bubble grows there is a leak.
16
Figure 16
Locking shut off
Collar
(b)
Quick disconnect
engaged
Figure 17
Outside
house wall

Advertisement

Table of Contents