Clarke XR75 Operating & Maintenance Manual

Clarke XR75 Operating & Maintenance Manual

Paraffin/diesel heaters

Advertisement

Quick Links

PARAFFIN/DIESEL HEATERS
Model Nos.
XR75 - XR105 - XR 155
Part Nos.
6920270- 6920280 - 6920290
1200

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XR75 and is the answer not in the manual?

Questions and answers

Summary of Contents for Clarke XR75

  • Page 1 PARAFFIN/DIESEL HEATERS Model Nos. XR75 - XR105 - XR 155 Part Nos. 6920270- 6920280 - 6920290 1200...
  • Page 2 2. Faulty Motor/Capacitor 2. Check and if necessary, replace This CLARKE product is guaranteed against faulty manufacture for a period of 12 3. Lock out of appliance 3. Detect cause of overheating. months from the date of purchase. Please keep your receipt as proof of purchase.
  • Page 3 58 Blanking Plate plugged in. 59 Blanking Plate Screw • NEVER cover or impede air flow into or out of heater. - Clarke Labels /Decals • NEVER attach duct work to the front of heater. #...See your Clarke dealer •...
  • Page 4 Connect the mains lead to a standard, 230 Volt (50Hz) electrical supply through Part No. Part No. Part No. Description an approved 13 amp BS 1363 plug, or a suitably fused isolator switch. No. Description XR75 XR105 XR155 WARNING! THIS APPLIANCE MUST BE EARTHED Grille AX1001039711 AX1001039811...
  • Page 5: Wiring Diagram

    Wiring Diagram Legend FC - Photocell FS - In-Line Fuse Motor T/R - Transformer IN - ON/OFF Switch Thermostat External Thermostsat A suitable external thermostat for measuring ambient temperature, should be fitted between points X and Y (Wiring diagram), by a qualified electrician only. UNPACKING ref.
  • Page 6: Fuel Filter

    Height (mm) Please note that the details and specifications contained herein, are correct at the time of going to print. However, CLARKE International reserve the right to change specifications at any time without prior notice. Always consult the machine’s data plate...
  • Page 7 Relief Valve, and a plug for installing a Pressure Gauge as shown in fig. 5. NOTE: In the case of MODEL XR75, there is insufficient room to store the blanking plate in the Remove the plug, and install a gauge with a resolution of at least 0.02 bar (0.3psi).
  • Page 8 Thoroughly dry before re-installing. XR155 0.43 In dusty environments it may be necessary to carry out this procedure weekly. eg. For XR75, a 3ft window must be open by 10" minimum Never allow the filter to get blocked.. Fig. 4 Ignition Electrodes PARTS &...