Rimage 2000i User Manual page 29

Robotic-controlled autoloader
Hide thumbs Also See for 2000i:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
a.
Loosen the Torx T25 screws (Qty. 2) at the front of the printer until you can move the printer from side to side.
b.
Gently grasp the small metal tabs (Qty. 2) on the printer.
c.
Move the printer to the left or right as needed.
d.
Repeat step 3 to check the printer alignment.
e.
If necessary, repeat step b - step d until the printer is properly aligned from side to side.
f.
When the printer is properly aligned, tighten the Torx T25 screws (Qty. 2) to ensure continued alignment.
7.
Align the printer from front to back.
a.
Using a 5/32" Allen wrench, turn the center front 5/32" Allen screw (Qty. 1).
Turn the Allen screw clockwise to move the printer toward the front of the Rimage 2000i.
Turn the Allen screw counterclockwise to move the printer toward the back of the Rimage 2000i.
b.
Repeat step 3 to check the printer alignment.
c.
If necessary, repeat step 7 until the printer is properly aligned from front to back.
8.
Remove the disc from the printer tray.
9.
Press
. The printer tray closes.
10. Close the ink cartridge access door.
11. Press and hold the operator button until [EXIT TEST MODE DIAGNOSTIC] displays on the operator panel.
12. When [EXIT TEST MODE DIAGNOSTIC] displays on the operator panel, release the operator button.

Note: If [PAUSE...] displays on the operator panel, press and release the operator button. [RIMAGE 2000i READY]
displays on the operator panel.
The Rimage 2000i is ready for use.
100763_M
Metal Tabs
Maintain the Rimage 2000i
29