Selecting The Mode Of Output (Output) - Electro-Voice Contractor Precision CPS4.5 Owner's Manual

Contractor precision series
Hide thumbs Also See for Contractor Precision CPS4.5:
Table of Contents

Advertisement

Available languages

Available languages

CONTRACTOR PRECISION SERIES

2.7 Selecting the Mode of Output (OUTPUT)

Different output modes are available for the amplifier's output channels. Each channel can be switched to high impedance
mode (HZ) for driving 70 V or 100 V loudspeakers without output transformers (Direct Drive).
In DUAL or PARALLEL mode each output channel's OUTPUT setting can be independently set. In BRIDGED mode for each
pair of outputs only the OUTPUT setting of the channel with odd number (1, 3, 5 or 7) matters, the OUTPUT setting of the
channel with even number (2, 4, 6 or 8) is ignored.
Following section describes the four different OUTPUT settings of CPS amplifiers.
2 Ohm Mode / VLD Mode
In 2 Ohm mode the power amplifier reaches maximum output power having a load of 2 Ω connected. Up to 4 cabinetts having
a nominal impedance of 8 Ω each can be driven by each amplifier channel. This mode should be used if a high number of
speaker with medium or low power rating should be driven in low impedance mode (LZ). The VLD mode (Remote Control
Module required) allows adjusting the output power of the amplifier channel. Please see page 11 for details about VLD mode.
4 Ohm Mode
In 4 Ohm mode the power amplifier reaches maximum output power having a load of 4 Ω connected. Up to 2 cabinetts having
a impedance of 8 Ω each can be driven by each amplifier channel. This mode should be used if speakers with high power
rating (e.g. Subwoofers) should be driven in low impedance mode (LZ).
10
Owner's Manual
Illustration 2.4: DUAL mode of CH 1 and CH 2 in 2 Ohm Mode
Illustration 2.5: DUAL mode of CH 1 and CH 2 in 4 Ohm Mode

Advertisement

Table of Contents
loading

Table of Contents