Table; Cisco Asr 9912 Router Dc Electrical Specifications - Cisco ASR 9001-S Overview And Reference Manual

Asr 9000 series aggregation services router
Hide thumbs Also See for ASR 9001-S:
Table of Contents

Advertisement

Appendix A
Technical Specifications
Table A-15
Description
Source DC service
requirement
Redundancy
1. For each DC power supply module. Some power/chassis configurations may operate at lower current ratings than those
specified in this table. Contact your Cisco technical representative for more information.
Note
Table A-16
Table A-16
Description
Power modules per system
Total DC input power per
power module
Rated input voltage per
power module
Input current draw
Source DC service
requirement
Redundancy
1. For each DC power supply module. Some power/chassis configurations may operate at lower current ratings than those
specified in this table. Contact your Cisco technical representative for more information.
Note
OL-17501-09
Cisco ASR 9922 Router DC Electrical Specifications (continued)
Value
Sufficient to supply the rated input current. Local codes apply.
1
DC power modules operate in N+1 redundancy mode. Up to sixteen
DC power modules are supported. The number of DC power modules
needed depends on the configuration of the chassis (e.g. number of line
cards, RPs, and FC cards installed). Use the Cisco Power Calculator
(Cisco.com account required) at
to calculate how many DC power modules are needed.
Both the AC-powered and DC-powered versions of the Cisco ASR 9922 Router support only
version 2 power systems.
lists the DC electrical specifications for the Cisco ASR 9912 Router.

Cisco ASR 9912 Router DC Electrical Specifications

Value
Version 2 power system:
Up to 12 DC power modules per system, four per tray
Version 2 power system:
2300 W (2100 W output module)
–48 VDC nominal in North America
–60 VDC nominal in the European Community
(Range: –40.5 to –72 VDC [–75 VDC for 5 ms])
1
49 A maximum at –48 VDC nominal
39 A maximum at –60 VDC nominal
Sufficient to supply the rated input current. Local codes apply.
1
DC power modules operate in N+1 redundancy mode. Up to 12 DC
power modules are supported. The number of DC power modules
needed depends on the configuration of the chassis (e.g. number of line
cards, RPs, and FC cards installed). Use the Cisco Power Calculator
(Cisco.com account required) at
to calculate how many DC power modules are needed.
Both the AC-powered and DC-powered versions of the Cisco ASR 9912 Router support only
version 2 power systems.
Cisco ASR 9000 Series Aggregation Services Router Overview and Reference Guide
http://tools.cisco.com/cpc/launch.jsp
http://tools.cisco.com/cpc/launch.jsp
A-11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents