IMPORTANT SERVICE NOTES (For U.S.A.Only)

BEFORE RETURNING THE AUDIO PRODUCT
(Fire & Shock Hazard)
Before returning the audio product to the user, perform the
following safety checks.
1. Inspect all lead dress to make certain that leads are not
pinched or that hardware is not lodged between the chassis
and other metal parts in the audio product.
2. Inspect all protective devices such as insulating materials,
cabinet, terminal board, adjustment and compartment
covers or shields, mechanical insulators etc.
3. To be sure that no shock hazard exists, check for leakage
current in the following manner.
* Plug the AC line cord directly into a 120 volt AC outlet.
* Using two clip leads, connect a 1.5k ohm, 10 watt resistor
paralleled by a 0.15 F capacitor in series with all exposed
metal cabinet parts and a known earth ground, such as
conduit or electrical ground connected to earth ground.
* Use a VTVM or VOM with 1000 ohm per volt, or higher,
sensitivity to measure the AC voltage drop across the
resistor (See diagram).
* Connect the resistor connection to all exposed metal parts
having a return path to the chassis (antenna, metal cabinet,
screw heads, knobs and control shafts, escutcheon, etc.)
and measure the AC voltage drop across the resistor.
The voltage selector is located on the AC voltage selector box. If adjustment is necessary, ensure to remove plug of AC cord from
AC socket and use a screwdriver in order to turn the selector in either direction. The correct voltage figure is displayed in the window
below to the adjustment screw.
QACCB0008AW00
QACCE0007AW00
QACCJ0006AW00

VOLTAGE SELECTION(For MD-MX30W)

Figure 3 POWER SUPPLY CORD
AC SCALE
1.5k ohms
TEST PROBE
TO EXPOSED
METAL PARTS
All check must be repeated with the AC line cord plug connection
reversed.
Any reading of 0.3 volt RMS (this corresponds to 0.2 milliamp.
AC.) or more is excessive and indicates a potential shock
hazard which must be corrected before returning the audio
product to the owner.
QACCA0004AW00
QACCL0002AW00
– 3 –
MD-MX30/MX30W
VTVM
10W
0.15 µ F
CONNECT TO
KNOWN EARTH
GROUND