TECHNICAL DETAILS

Loading Info:
Grill Burner
Heat Input
Injector Marking
Top Oven*
Heat Input
Injector Marking
Flame Supervision Device
Thermostat
Thermostat By-Pass Marking
Main Oven
Heat Input
Injector Marking
Flame Supervision Device
Thermostat
Thermostat By-Pass Marking
Oven Light:
Control Cooling Fan
Timer:
Height:
Width:
Depth:
(excluding handles and knobs)
Weight:
Connection:
Gas
Electric
* Cannot be used at the same time as the grill burner
IMPORTANT - SAFETY REQUIREMENTS
This appliance must be installed in accordance with the Gas Safety (Installation and Use) Regulations
Current Editions. Detailed recommendations are contained in the following British Standard Codes of
Practice - BS.6172, BS.5440: Part 2 and BS.6891. All British Standards must be 'Current Editions'.
PROVISION FOR VENTILATION
This appliance is not connected to a combustion products evacuation device. It shall be installed and
connected in accordance with the current installation regulations. Particular attention shall be given to
the relevant requirements regarding ventilation.
The room containing the appliance should have an air supply in accordance with BS. 5440: Part 2
Current Edition. All rooms require an openable window or equivalent and some rooms will require a
permanent vent as well. For room volumes up to 5m³ an air vent of 100cm² is required: for room
volumes between 5m³ and 10m³ an air vent of 50cm² is required. If the room has a door that opens
directly to the outside, no air vent is required. For room volumes that exceed 11m³ no air vent is
required. If there are other fuel burning appliances in the same room, BS.5440: Part 2 Current Edition
should be consulted to determine the requisite air vent requirements.
Prolonged intensive use of the appliance may call for additional ventilation, for example opening a
window, or more effective ventilation, for example increasing the level of mechanical ventilation where
present.
40
Natural Gas
2.8kW (9554 Btu/h)
123
1.7kW (5800 Btu/h)
095
Diamond 'H' GSD 100/48
Sourdillon 63503/982
Fixed Internal
1.7kW (5800 Btu/h)
095
Diamond 'H' GSD 100/28
Diamond 'H' 1100 -122/B2
74
0.05kW
0.020kW
0.005kW
Appliance
760 mm
593 mm
535 mm
49kg
Rear top right hand side of
appliance Rc½ (½" B.S.P.
Female

230/240 Volt A.C. 50Hz Mains 3 core cable and
moulded plug fused to 3 amps.
L.P. Gas
2.8kW 201 g/h
089
1.7kW 122 g/h
Diamond 'H' GSD 100/49
Sourdillon 64063/982
Fixed Internal
1.7kW 122 g/h
Diamond 'H' GSD 100/30
Diamond 'H' 1100 -123/B2
79
Installed
720 mm