Remington 482 Operating Instructions Manual page 9

Powder actuated fastening tool
Table of Contents

Advertisement

30
482-45
2. Should the tool fail to fire, hold the muzzle firmly against the work surface for 30
seconds. Release the trigger and remove pressure on the tool while holding the
muzzle against the work surface. Again press the tool firmly against the work surface
and pull the trigger. If the tool still fails to fire, hold the tool firmly against the work
surface for another 30 seconds before unloading and carefully discarding the
misfired power load into water or oil.
482-47
3. ALWAYS use the spall shield when driving directly into concrete or steel. Always
wear approved goggles.
482-49
4. NEVER use a powder actuated tool in an explosive or flammable atmosphere or
when non-sparking tools are required.
POWER LOADS AND FASTENERS
1. NEVER leave unfired power loads on floors or work surfaces.
106088
Safety Precautions
WATER
482-48
GAS
GASOLINE
OLINE
482-50
9