Technical Specifications
Environment
Electrical characteristics Description
Safety
Emissions
Immunity
DA - 13267 Worldwide — Version 19 — November 22, 2013
MAC address table size
Operating temperature
Operating relative
humidity
Nonoperating/Storage
temperature
Nonoperating/Storage
relative humidity
Alitude
Acoustic
Maximum heat
dissipation
Voltage
Idle power
Maximum power rating
Frequency
Notes
CSA 22.2 No. 60950; EN 60950/IEC 60950; UL 60950
FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Power frequency
magnetic field
Voltage dips and
interruptions
Harmonics
Flicker
HP 6600 Switch Series
64000 entries
41°F to 104°F (5°C to 40°C)
15% to 80% @ 104°F (40°C), noncondensing
-40°F to 158°F (-40°C to 70°C)
15% to 90% @ 158°F (70°C), noncondensing
up to 10,000 ft (3 km)
Power: 71.8 dB, Pressure: 63.4 dB ISO 7779, ISO
9296
The switch automatically adjusts to any voltage
between 100-120 and 200-240 V with either 50 or
60 Hz.
890 BTU/hr (938.95 kJ/hr)
100-120/200-240 VAC
226 W
261 W
50/60 Hz
Idle power is the actual power consumption of the
device with no ports connected.
Maximum power rating and maximum heat
dissipation are the worst-case theoretical
maximum numbers provided for planning the
infrastructure with fully loaded PoE (if equipped),
100% traffic, all ports plugged in, and all modules
populated.
EN 55024, CISPR 24
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-11
EN 61000-3-2, IEC 61000-3-2
EN 61000-3-3, IE 61000-3-3