6-2. Wiring Instructions For Optional 240 Volt, Single-Phase Plug (NEMA 14-50P)

Tools Needed:
SECTION 7 – MAINTENANCE AND TROUBLESHOOTING

7-1. Maintenance Label

1
3
4
120V
120V
240V
6
2
3
4
240V
6
5
The plug can be wired for a 240 V,
2-wire load or a 120/240V, 3-wire
load. See circuit diagram.
1
Plug Wired for 120/240 V,
3-Wire Load
When wired for 120 V loads, each
duplex receptacle shares a load
with one half of 240 V receptacle.
2
Plug Wired for 240 V, 2-Wire
5
Load
3
Neutral (Silver) Terminal
4
Load 1 (Brass)Terminal
5
Load 2 (Brass) Terminal
6
Ground (Green) Terminal
Strip cord jacket back enough to
separate conductors.
Strip conductors enough to make
good contact with plug terminals.
Make plug connections and rein-
stall outer shell and cord grip.
Tighten assembly screws onto
shell. Do not overtighten.
Plug1 7/99 – ST-120 813-D
OM-4401 Page 25