Wiring Instructions For Optional 240 Volt, Single-Phase Plug (Nema 14-50P) - Miller Electric 280 NT Owner's Manual

Engine driven welding generator
Table of Contents

Advertisement

7-3. Wiring Instructions For Optional 240 Volt, Single-Phase Plug (NEMA 14-50P)

Current Available in Amperes
240 V
Each 120 V Duplex
Receptacle*
Receptacle
20
0
15
5
10
10
5
15
0
20
V x A = Watts
*One 240 V load or two 120 V loads.
OM-4430 Page 32
.
7
4
120V
120V
240V
4
240V
240 V AC
120 V AC
120 V AC
A complete Parts List is available at www.MillerWelds.com
The plug can be wired for a 240 V,
2-wire load or a 120/240V, 3-wire
load. See circuit diagram.
1
Plug Wired for 120/240 V,
3-Wire Load
When wired for 120 V loads, each
duplex receptacle shares a load
with one half of 240 V receptacle.
2
Plug Wired for 240 V, 2-Wire
Load
1
3
3
Neutral (Silver) Terminal
4
Load 1 (Brass)Terminal
5
Load 2 (Brass) Terminal
6
Ground (Green) Terminal
7
Amperes Available using
120/240 V Plug
5
6
2
3
6
5
Tools Needed:
plug1 11/03 − 120 813-D

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Legend 302

Table of Contents