  • ENGLISH, page 17
Connect the high pressure hose
to the trigger gun
Illustration
Push the high pressure hose into
the trigger gun until it locks audibly.
Note: Make sure the connection
nipple is aligned correctly.
Check the secure connection by
pulling on the high pressure hose.

Water supply

Warning
According to the applicable
regulations, the appliance
must never be used on the
drinking water supply without a
system separator. Use a suitable
system separator manufactured
by KÄRCHER; or, as an alterna-
tive, a system separator as per
EN 12729 Type BA.
Water flowing through a system
separator is considered non-
drinkable.
Caution
Always connect the system sep-
arator to the water supply, never
directly to the appliance!
Note: Impurities in the water can dam-
age the high-pressure pump and ac-
cessories. For protection, the use of
the KÄRCHER water filter (optional ac-
cessory, order no. 4.730-059) is rec-
ommended.
Water supply from mains
Observe regulations of water supplier.
For connection values, see type plate/
technical data.
Use a fibre-reinforced water hose
(not included) with a standard cou-
pling. (Minimum diameter 1/2 inch
(13 mm), minimum length 7.5 m).
22
Caution
Hose couplings made of metal
with aquastop can damage the
pump! Please use plastic cou-
plings or KÄRCHER brass cou-
plings.
Illustration
Screw the coupling element to the
water connection on the appliance.
Push the water supply hose onto
the coupling unit, then connect it to
the water supply.
Drawing in water from open
reservoirs
This high-pressure cleaner is suited to
work with the KÄRCHER suction hose
with backflow valve (Optional accesso-
ry, order no. 4.440-238) to draw in sur-
face water, e.g. from water butts or
ponds (see specifications for max. suc-
tion height).
Fill the KÄRCHER suction hose
with backflow valve with water,
screw to water supply and hang into
the water butt.
Appliance ventilation: Switch the
appliance on with the high-pressure
hose detached and operate (max. 2
minutes) until the water exits the
high-pressure connection without
bubbles. Switch off appliance and
reconnect high-pressure hose.
Caution
Dry runs lasting longer than two
minutes lead to damages to the
high pressure pump. If the appli-
ance does not build up pressure
within two minutes, switch it off
and proceed as instructed in the
Chapter "Troubleshooting".