IBM xSeries 330 Hardware Maintenance Manual page 122

Type 8675
Hide thumbs Also See for xSeries 330:
Table of Contents

Advertisement

Error Code/Symptom
035-253-S99 (RAID adapter initialization
failure)
089-XXX-001 (Failed Microprocessor test)
089-XXX-002 (Failed Optional
Microprocessor test)
165-060-000 (Service Processor: ASM may
be busy)
165-198-000 (Service Processor: Aborted)
165-201-000 (Service Processor: Failed)
165-330-000 (Service Processor: Failed)
165-342-000 (Service Processor: Failed)
180-XXX-000 (Diagnostics LED failure)
180-XXX-001 (Failed Front LED panel test)
180-XXX-002 (Failed Diagnostics LED panel
test)
180-XXX-003 (Failed System Board LED
test)
180-XXX-005 (Failed SCSI Backplane LED
test)
201-XXX-0NN (Failed Memory test, see
"Memory Settings" on page 34)
118
Hardware Maintenance Manual: xSeries 330 Type 8675
FRU/Action
1. ServeRAID Adapter in slot S is not configured properly. Obtain
the basic and extended configuration status and refer to the
ServeRAID Hardware Maintenance Manual for more information.
2. Cable
3. SCSI Backplane
4. Adapter
1. Microprocessor 1
2. System Board
1. Microprocessor 2
2. System Board
1. Rerun the diagnostic test
2. Fix other error conditions that may be keeping ASM busy. Refer to
the error log and diagnostic panel.
3. Disconnect all server and option power cords from server, wait 30
seconds, reconnect, and retry.
4. System Board
1. Rerun the diagnostic test
2. Fix other error conditions that may be keeping ASM busy. Refer to
the error log and diagnostic panel.
3. Disconnect all server and option power cords from server, wait 30
seconds, reconnect, and retry.
4. System Board
1. Disconnect all server and option power cords from server, wait 30
seconds, reconnect, and retry.
2. System Board.
1. Update to the latest ROM diagnostic level, and retry.
1. Ensure latest firmware levels for ASM and BIOS.
2. Disconnect all server and option power cords from server, wait 30
seconds, reconnect, and retry.
3. System Board
1. Run Diagnostic LED test for the failing LED.
1. Information LED Panel
1. System Board
1. System Board
1. SCSI Backplane
2. SCSI Backplane Cable
3. System Board
1. DIMM Location slots 1-4 where NN = DIMM location.
Note: NN 1=DIMM 1 NN 2=DIMM 2 NN 3=DIMM 3 NN
4=DIMM 4
2. System Board

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xseries 330 8675

Table of Contents