HP SPECIFIC KNOWN ISSUES

Problem Description: Issuing an "End to End Connectivity" to the EVA4400/6400/8400 may
crash both EVA controllers at the same time.
Workaround: None.
Problem Description: Issuing an fcping to the EVA4400/6400/8400 may crash the EVA
controller
Workaround: None.
Problem Description: If it becomes necessary to move an EVA controller port to a different
port on the same C-series switch or to a port on a different C-series switch, the corresponding
controller port may become unavailable.
Workaround: Restart the EVA controller.
Problem Description:
and P2000 FC G3 storage arrays may display as servers in the Fabric Manager or Data Center
Network Manager topology diagram or host ports list.
Workaround: Perform the following steps to change the display of the array from a host icon to
a storage icon.
1. Log into Fabric Manager or Data Center Network Manager
2. Under "Physical Attributes" open "End Devices"
3. Select "Hosts" and click on the "Enclosures" tab in the Information Pane
4. Under "Device Type" for the desired device, in Fabric Manager select "Disk", or for
Data Center Network Manager select "Storage"
5. Save changes by selecting the "Apply Changes" icon on the top left corner of the
Information Panel
Problem Description: HP C-class fibre channel mezzanine cards may not log into the embedded
C-series fibre channel switch at the supported speed and mode.
Workaround: Set the internal switch port from auto to the supported speed and mode.
Problem Description:
"Unknown" vendor in Data Center Network Manager Host Ports list.
Workaround: Enabling the FDMI in Emulex driver by setting the driver parameter EnableFDMI
to 1 will allow Data Center Network Manager to display the vendor name.
Problem Description:
in Data Center Network Manager Switches list.
Workaround: Right click the entry in the switch list and select Purge, then click the refresh icon
in the task bar.
Note: Refer to the Cisco MDS NX-OS release notes for a full list of open and closed caveats.