Completing The Installation - HP MSA 30 User Manual

Formerly hp storageworks model 4400 family of ultra320 scsi disk enclosures
Table of Contents

Advertisement

Completing the Installation

1. Reinstall the components in the system. For details, refer to Chapter 3.
2. Connect cables from the VHDCI sockets on the I/O modules to the
corresponding connectors on a controller system. If you need additional cables,
order according to the information in the following table.
Table 2-1: Supported SCSI Cables
Connector Type
Standard Cables
68-pin VHDCI
68-pin Offset VHDCI
Optional Cables
68-pin VHDCI
68-pin Offset VHDCI
3. Connect the AC input sockets of each power supply unit to an AC power source.
NOTE: Having two power supply units eliminates the power supply unit as a single point
of failure. This is the preferred, high-availability configuration. For complete power
redundancy, each power supply unit should be connected to a separate AC power source.
4. Confirm that the system components are all functioning normally by observing
the condition of their status LEDs, as described in the next section.
HP StorageWorks Modular Smart Array 30 User Guide
Length
3.0 m (10 ft)
3.7 m (12 ft)
1.0 m (3.3 ft)
2.0 m (6.6 ft)
5.0 m (16 ft)
1.8 m (6 ft)
7.3 m (24 ft)
12 m (39 ft)
CAUTION: The disk system does not have power switches. Be sure that the
system is correctly configured before connecting the power cords.
Installing the System in a Rack
Part Number
189505-B21
342175-B21
168256-B21
168257-B21
116454-B21
341174-B21
164604-B21
150214-B21
2-7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks modular smart array 30

Table of Contents