Check Valve:
When the air
compressor is
operating, the
check valve is
"open",
allowing
compressed air
to enter the air
tank. When the
air compressor
reaches "cut-
out" pressure, the check valve
"closes", allowing air pressure to
remain inside the air tank.
Air Intake Filter (not shown): This
filter is designed to clean air coming
into the pump. This filter must always
be clean and ventilation openings free
from obstructions. See Maintenance.
Motor Overload Protector: The motor
has a thermal overload protector. If
the motor overheats for any reason,
the overload protector will shut off the
motor. The motor must be allowed to
cool down before restarting. To restart:
1.
Set the Auto/Off switch to "Off"
and unplug unit.
2.
Allow the motor to cool.
3.
Plug the power cord into the
correct branch circuit receptacle.
4.
Set the Auto/Off lever to "Auto"
position.
HOW TO USE YOUR UNIT
How to Stop
Set the Auto/Off switch to "Off".
Before Starting
and understand this instruction
manual for safety, operation and
maintenance instructions.
Before Each Start-Up
1.
Place Auto/Off switch to "Off".
2.
Plug the power cord into the
correct branch circuit receptacle.
(Refer to Voltage and Circuit
Protection paragraph in the
Installation section of this
manual.)
Check
Valve
Do not operate this
unit until you read
3.
Pull regulator knob out, turn coun-
terclockwise until it stops. Push
knob in to lock in place.
4.
Attach hose and accessories.
NOTE: The hose or accessory will
require a quick connect plug if the
air outlet is equipped with a quick
connect.
grasp air hose in hand when
installing or disconnecting to
prevent hose whip.
use damaged or worn accessories.
hazardous risk of bursting. Check
the manufacturer's maximum
pressure rating for air tools and
accessories. The regulator outlet
pressure must never exceed the
maximum pressure rating.
Compressed air from the unit may
contain wa ter condensation and
oil mist. Do not spray un fil tered air
at an item that could be damaged
by moisture. Some air tools and
accessories may require filtered air.
Read the in struc tions for the air tools
and accessories.
How to Start
1.
Turn the Auto/Off switch to "Auto"
and allow tank pressure to build.
Motor will stop when tank pres-
sure reaches "cut-out" pressure.
2.
Pull the regulator knob out and
turn clockwise to increase
pressure. When the desired
pressure is reached push knob in
to lock in place. The compressor
is ready for use.
is noticed, stop the compressor
immediately and have it checked by
a trained service technician.
The compressor is ready for use.
14- ENG
Risk of unsafe
operation. firmly
Risk of unsafe
operation. Do not
Too much air
pressure causes a
Risk of unsafe
operation.
If any unusual
noise or vibration

Hide quick links: