KNOW YOUR AIR COMPRESSOR

READ THIS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING
YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with
the location of various controls and adjustments. Save this manual for future
reference.

Description of Operation

Become familiar with these controls
before operating the unit.
Pressure
Switch
regulator
Outlet
Pressure
Gauge
Quick Connect
Auto (I)/Off (O) Switch: Turn this
switch "Auto (I)" to provide automatic
power to the pressure switch and
"Off (O)" to remove power at the end
of each use.
Pressure Switch: The pressure switch
automatically starts the motor when
the air tank pressure drops below the
factory set "cut-in" pressure. It stops
the motor when the air tank pressure
reaches the factory set "cut-out" pres-
sure.
Safety Valve: If the pressure switch
does not shut off the air compressor
at its "cut-out" pressure setting, the
safety valve will protect against high
pressure by "popping out" at its fac-
tory set pressure (slightly higher than
the pressure switch "cut-out" setting).
Outlet Pressure Gauge: The outlet
pressure gauge indicates the air pres-
sure available at the outlet side of the
regulator. This pressure is controlled
by the regulator and is always less
than or equal to the tank pressure.

OPERATION

Auto (I)/Off
(O) Switch
Safety
Valve
Tank
Pressure
Gauge
13 - ENG
Tank Pressure Gauge: The tank pres-
sure gauge indicates the reserve air
pressure in the tank.
Regulator: Controls the air pressure
shown on the outlet pressure gauge.
Pull the knob out and turn clockwise
to increase pressure and counterclock-
wise to decrease pressure. When the
desired pressure is reached push knob
in to lock in place.
Universal Quick-Connect Body: The
universal quick-connect body accepts
the three most popular styles of quick-
connect plugs: Industrial, automotive
(Tru-flate), and ARO. One hand push-
to-connect operation makes connec-
tions simple and easy.
Drain Valve:
The drain valve
is located at
the base of the
air tank and is
used to drain
condensation
at the end of each use.
Cooling System (not shown): This
compressor contains an advanced
design cooling system. At the heart of
this cooling system is an engineered
fan. It is perfectly normal for this fan to
blow air through the vent holes in large
amounts. You know that the cooling
system is working when air is being
expelled.
Air Compressor Pump (not shown):
Compresses air into the air tank.
Working air is not available until the
compressor has raised the air tank
pressure above that required at the air
outlet.
Drain