Download Print this page

Craftsman 919.152144 Owner's Manual page 13

Permanently lubricated tank mounted air compressor
Hide thumbs Also See for 919.152144:

Advertisement

Available languages

Available languages

Air Compressor
Pump (not shown):
Compresses
air into the air tank.
Working air is not available until the
compressor
has raised the air tank
pressure above that required at the
air outlet.
Check Valve:
When the air
compressor
is operating, the check
valve is "open", allowing compressed
air to enter the air tank. When the air
compressor
reaches "cut-out"
pressure, the check valve "closes",
allowing air pressure to remain inside
the air tank.
Check
Valve
How to Use Your Unit
How to Stop:
1.
Set the On/Auto/Off
lever to
"OFF".
Before
First Start-up
Break-in Procedure
_Risk
of Unsafe
Operation. Serious
damage may result if the following
break-in instructions are not
closely followed.
This procedure is required before the
air compressor
is put into service and
when the check valve or a complete
compressor
pump has been
replaced.
1.
Make sure the On/Auto/Off
lever
is in the "OFF" position.
NOTE: Pull coupler back until it clicks
to prevent air from escaping through
the quick connect.
2.
Plug the power cord into the
correct branch circuit receptacle.
(Refer to Voltage and Circuit
Protection paragraph in the
Installation section of this
manual.)
3.
Open the drain
valve fully to
permit air to
escape and
Open Drain
prevent air
Valve
pressure build up in the air tank
during the break-in period.
4.
Move the On/Auto/Off
lever to
"ON/AUTO"
position. The
compressor will start.
5.
Run the
compressor for 15
minutes. Make
sure the drain
valve is open and
Closed Drain
there is minimal air
Valve
pressure build-up
in tank.
6.
After 15 minutes, close the drain
valve. The air receiver will fill to
"cut-out"
pressure and the motor
will stop.
The compressor is now ready for use.