Download Print this page
Craftsman 919.152144 Owner's Manual
Craftsman 919.152144 Owner's Manual

Craftsman 919.152144 Owner's Manual

Permanently lubricated tank mounted air compressor
Hide thumbs Also See for 919.152144:

Advertisement

Available languages

Available languages

Quick Links

Owner's
Manual
I CRRFTglVlRN°I
Permanently
Lubricated
Tank Mounted
AiR COMPRESSOR
Model No.
919.152144
=
Safety Guidelines
=
Assembly
=
Operation
=
Maintenance
=
Service
and Adjustments
=
Troubleshooting
=
Repair
Parts
CAUTION:
Read the Safety Guidelines
and All Instructions Carefully Before
Operating.
Sears,
Roebuck
and Co., Hoffman
Estates,
IL 60179
U.S.A.
Visit our Craftsman website: www.sears.com/craftsman
A02265
Rev. 3 9/1/04

Advertisement

loading

Summary of Contents for Craftsman 919.152144

  • Page 1 Safety Guidelines Assembly Operation Maintenance Service and Adjustments Troubleshooting Repair Parts CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating. Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Visit our Craftsman website: www.sears.com/craftsman A02265 Rev. 3 9/1/04...
  • Page 2 FULL ONE YEAR WARRANTY AiR COMPRESSOR If this CRAFTSMAN Air Compressor fails due to a defect in material or workmanship within one year from the date of purchase, Sears will at its option repair or replace it free of charge. Contact your nearest Sears...
  • Page 3: Glossary

    Model No. 919,152144 Max. Developed Running HP Bore 47.625 Stroke 31.75 Voltage-Single Phase 120V Minimum Branch Circuit Requirement 10 amps Fuse Type Time Delay Air Tank Capacity Approx. Cut-In Approx. Cut-out SCFM @ 40 psig SCFM @ 90 psig Refer to Glossary for abbreviations.
  • Page 4 Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. WARNING: Risk of explosion or fire ,_,i What Could Happen Hew To Prevent it is normal for electrical...
  • Page 5: Accessories

    WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. What Could Happen Now To Prevent Failure to properly drain condensed Drain tank daily or after each use.
  • Page 6 WARNING: Risk of Electrical Shock How To Prevent it What Could Happen Your air compressor is powered Never operate the compressor outdoors electricity. Like any other electrically when it is raining or in wet conditions. powered device, if it is not used Never operate compressor with properly...
  • Page 7 WARNING: Risk of Burns What Could Happen How To Prevent it Never touch any exposed metal parts Touching exposed metal such as the on compressor during or immediately compressor head or outlet tubes, can after operation. Compressor will remain result in serious burns.
  • Page 8 WARNING: Risk of Electrical Shock How To Prevent it What Could Happen Your air compressor is powered Never operate the compressor outdoors electricity. Like any other electrically when it is raining or in wet conditions. powered device, if it is not used Never operate compressor with properly...
  • Page 9 Become familiar with these terms When the tank pressure drops to a certain low level the motor will restart before operating the unit. automatically. The low pressure CFM: Cubic feet per minute. at which the motor automatically SCFM: Standard cubic feet per restarts is called "cut-in"...
  • Page 10: Installation

    HOW TO SET UP YOUR UNiT iMPORTANT: The outlet being used must be installed and grounded in accordance with all local codes and ordinances. Location of the Air Compressor Make sure the outlet being used Locate the air compressor in a has the same configuration clean, dry and well ventilated area.
  • Page 11: Operation

    Extension Cords Voltage and Circuit Protection Refer to the specification chart for the Using extension cords is not recommended. The use of extension voltage and minimum branch circuit requirements. cords will cause voltage to drop resulting in power loss to the motor _Risk of Unsafe and overheating.
  • Page 12 Know Your Air Compressor READ THIS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Quick Switch Connect Tank Regulator...
  • Page 13 This procedure is required before the Air Compressor Pump (not shown): Compresses air into the air tank. air compressor is put into service and Working air is not available until the when the check valve or a complete compressor has raised the air tank compressor pump has been replaced.
  • Page 14 How to Start: Before Each Start=Up: Place On/Auto/Off lever to Turn the On/Auto/Off lever to "OFF" and close air regulator. "AUTO" and allow tank pressure to build. Motor will stop when Pull regulator knob out, turn tank pressure reaches "cut-out" counterclockwise until it stops.
  • Page 15 Customer Responsibilities Before Daily each or after each Check Safety Valve • Drain Tank • To Drain Tank Risk of Unsafe Set the On/Auto/Off lever to Operation. Unit cycles "OFF" and unplug unit. automatically when power is on. When servicing, you may Pull the regulator knob out and be exposed to voltage sources,...
  • Page 16: Maintenance

    NOTE: The hose clamp is not ALL MAINTENANCE AND REPAIR reusable. You must purchase a OPERATIONS NOT LISTED MUST new hose clamp, see the Parts List BE PERFORMED BY A TRAINED Manual or purchase a standard hose SERVICE TECHNiCiAN. clamp at a local hardware store. Unscrew the check valve (turn Risk of Unsafe Operation.
  • Page 17 Assemble the regulator and To Replace Regulator orient as shown. Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section. Set the On/Auto/Off lever to "OFF" and unplug unit. Regulator Using an adjustable wrench remove the outlet pressure gauge and quick connect from the regulator.
  • Page 18 Before you store the air compressor, Risk of Bursting. make sure you do the following: Water will condense in the air tank. If not Review the "Maintenance" drained, water will corrode section on the preceding weaken the air tank causing a risk pages and perform scheduled of air tank rupture.
  • Page 19: Service And Adjustments

    Risk of Unsafe Operation. Unit cycles automatically when power is on. When servicing, you may be exposed to voltage sources, compressed air, or moving parts. Before servicing unit unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool.
  • Page 20 PROBLEM CAUSE CORRECTION Pressure readinc It is normal for "some" If there is an excessive on the regulated pressure drop to occur. amount of pressure drop pressure gauge when the accessory is used, drops when an adjust the regulator following accessory is the instructions in the...
  • Page 21 PROBLEM CAUSE CORRECTION Regulator will Damaged regulator. Replace. not shut off air outlet. Motor will not Let motor cool off and Motor overload protection run. overload switch will switch has tripped. automatically reset. Tank pressure exceeds Motor will start automatically when tank pressure drops pressure switch "cut-in"...
  • Page 22 Air Compressor Model Number 9t9.152t44 A02265 22-ENG...
  • Page 23 Air Compressor Model Number 919.152144 PART NUMBER DESCRiPTiON Z-D24671 Tank 33T-108 Recess Rubber Bumper (3 used) 91895680 Screw (3 used) SSF-621 Screw (2 used) D30198 Nipple, 1/4-18 NPT X 2.50 AC-0430 Drain Valve D20114 Safety Valve D27253 Regulator D20675 Quick Connect 1/4 NPT Z-D27212 Gauge 2"...
  • Page 24 Air Compressor Model Number 919.152144 Torque 30-45 in.dbs. Torque 45-55 11-2 ® 11-1 Hand Tight Torque 10 in.qbs. A02265 24-ENG...
  • Page 25 Air Compressor Model Number 919.152144 PART NUMBER DESCRiPTiON CAC-1320 Shroud (left) D25735 Shroud (right) D25877 Head CAC-1212 Tube Seal D22253 Outlet Tube Z-D24819 Head Gasket Z-D29777 Valve Plate Assembly SSG-8169 O-Ring 2.132/2.0961D .073/.067W ÷+> ..Cylinder Sleeve ÷x SSF-3147 Screw, 3/8-16UNC Socket Head ÷>...
  • Page 26: Notes/Notas

    GARANTJA TOTAL DE UN ANO DEL COMPRESOR DE AIRE Si este compresor de aire Craftsman fallase debido a defectos de materiales o de fabricaci6n dentro del ano de su fecha de compra, Sears, a su opci6n, Io reparara o reemplazara sin costo alguno.
  • Page 27 Modelo N ° 919.152144 MAx. HP desarrollado Potencia de trabajo Di_metro interior 1,875 (47,625mm) Carrera 1,250 (31,75mm) 120V Voltaje-corriente manof_sica Circuito minimo requerido Tipo de fusibleAcci6n retardada Capacidad de aire en el tanque 4 Galones (15,1 litros) Presi6n de corte de entrada 120 psig Presi6n de corte de salida 150 psig...
  • Page 28 GUARDE ESTAS INSTRUCCIONES La operaci6n mantenimiento inadecuados este producto podrian ocasionar serias lesiones y dafios a la propiedad. Lea y comprenda todas advertencias e instrucciones de funcionamiento antes de utilizar este equipo. ADVERTENCIA: Riesgo de Explosi6n o Incendio puede occurrir c6mo prevenirio Para los contactos...
  • Page 29 H Zq ADVERTENCIA: Riesgo de E×plosibn I._1 Tanque de aire: las siguientes condiciones podrfan, causar el debilitamiento del tanque, determinar su explosi6n violenta, dafios a la propiedad o serias lesiones. qu_ puede occurrir c6mo prevenirlo Drenaje inadecuado del agua eondensada Drene el tanque diariamente o despu&e de en el tanque, siendo...
  • Page 30 ADVERTENCIA: Riesgo de Descarga El_ctrica puede occurrir c6mo prevenirlo Su compresor de aire esta accionado Jamas opere el compresor a la intemperie electricidad. Corno cualquier otro dispositivo cuando esta Iloviendo o en condiciones electrico impulsado electricamente, si no se Io humedad.Nunca opere el compresor sin sus...
  • Page 31 ADVERTENCIA: Riesgo de Quernaduras gU_ puede occurrir c6mo prevenirlo Tocar el metal expuesto tal como el cabezal Jam_s toque partes de metal expueetas en el del compresor o los tubos de salida del escape, compresor durante o inmediatamente despues puede ocaeionarle serias quemaduras, de la operaci6n,...
  • Page 32 ADVERTENCIA: Riesgo de Serias Lesiones o Da_os a la Propiedad Transportar el Compresor (Fuego, inhalaci6n, daSo a la euperficie de vehiculos) puede occurrir c6mo prevenirlo El aceite puede derramaree y ello podria Depoeite el compresor sobre una alfombrilla reeultar en seriae lesiones o la muerfe debido al protectora cuando Io transporte,...
  • Page 33 Presi6n minima de corte: Cuando Familiarfcese con los siguientes terminos, el motor est_ apagado, la presi6n del antes de operar la unidad: tanque de aire baja a medida que usted CFM: (Cubic feet per minute) Pies cLibicos continLia usando su accesorio. Cuando por minuto.
  • Page 34 COMO PREPARAR LA UNIDAD AsegOrese de que el tomacorriente que ser_ utilizado tenga la misma configuraci6n que el enchufe de Ubicaci6n del compresor de aire conexi6n a tierra. NO UTILICE UN Ubique al compresor de aire en una ADAPTADOR. Ver figura. zona limpia, seca y bien ventilada.
  • Page 35 Cables de extensi6n el_ctrica Protecci6n del voltaje y del circuito No so recomienda la utilizaci6n de cables Acerca del voltaje y la minima cantidad de extensi6n electrica. El uso de cables circuitos requeridos, refiSrase al cuadro de especificaciones. de extensi6n el_ctrica originara una ca[da de tensi6n, Io que determinar_ Riesgo de Operacidn perdida de potencia del motor asi come...
  • Page 36 Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DE OPERAR LA UNIDAD. Compare las ilustraciones contra su unidad a fin de familiarizarse con la ubicaci6n de los distintos controles y regulaciones. Conserve este manual para referencias futuras.
  • Page 37 AsegOrese que la palanca On/Auto/Off Bomba de cornpresi6n del aire (no este en la posici6n "OFF". mostrada): Comprime el aire dentro del Enchufe el cable de alimentaci6n en tanque. El aire de trabajo no se encuentra disponible hasta que el compresor haya el receptaculo del ramal del circuito alcanzado a Ilenar el tanque hasta un nivel...
  • Page 38 Antes de cada puesta en marcha: C6mo poner en marcha: Coloque el interruptor On/Auto/Off en la Mueva la palanca On/Auto/Off a posici6n "OFF" y cierre el regulador de la posici6n "AUTO" y deje que se aire. incremente la presi6n del tanque. El motor se detendra una vez alcanzado el Tire de la perilla del regulador, gire en valor de presi6n "de corte"...
  • Page 39 Responsabilidades del cliente Antes Diadamente cada s luegode cadaus(} Verifique la v_lvula de seguridad • Drenaje del tanque • C6mo drenar el tanque Riesgo de Operacibn Apagar la unidad colocando Insegura: La unidad arranca interruptor en On/Auto/OFF autorn_ticarnente cuande est_ "OFF".
  • Page 40 TODO TIPO DE MANTENIMiENTO NOTA: La abrazadera de la manguera no es Y OPERACIONES DE REPARACION reutilizable. Deber_ comprarse una nueva NO MENOIONADOS, DEBERAN SER abrazadera, ver la lista de partes del manual EFECTUADOS PeR PERSONAL TECNICO o compre una abrazadera estandar en ESPEClAMZADO.
  • Page 41 Ensamble el regulador y orientelo de Para reemplazar el regulador acuerdo a Io mostrado. Libere toda la preei6n del aire del tanque. Yea "Drenaje del tanque" en la eecci6n "Mantenimiento". Apagar la unidad colocando interruptor en On/Auto/OFF "OFF". Utilizando una Ilave regulable, extraiga el man6metro de presi6n externa y la conexi6n rapida del regulador.
  • Page 42 Antes de guardar su compresor de aire, Riesgo de asegOrese de hacer Io siguiente: Explesi6n. El Revise la secci6n "Mantenimiento" agua se condensa dentro del tanque de aire. Si no se drena, ella corroer_ de las paginas precedentes y ejecute debilitando la paredes del tanque el mantenimiento...
  • Page 43 Riesgo de Operaeibn Insegura: La unidad arranca autom_ticamente cuando est_ enchufada. AI hacer el mantenimiento, el operador puede quedar e×pueste a fuentes de corriente de aire comprimido o a piezas movibles. Antes de intentar hacer reparaciones, desconectar el compresor del tomacorriente, drenar la presibn de aire del tanque esperar a que el compresor...
  • Page 44 PROBLEMA CORREOOION CAUSA Si hubiese una ca[da excesiva La lectura de la Es normal que ocurra algL_n de presi6n durante el uso del presiOn sobre un descenso en la presi6n. accesorio, ajuste el regulador de man6metro acuerdo alas instrucciones de la viene equipado secci6n Operaci6n.
  • Page 45 PROBLEMA CORRECCION CAUSA El motor no Verifique la caja de fusibles Fusible fundido; interruptor funciona. observando la existencia de fusibles automatico del circuito disparado. fundidos y sustitQyalosen caso de necesidad. Restablezca el interruptor automatico. No use un fusible o interruptorautomaticocon valores que excedan los especificados para la rama de su circuito.
  • Page 46 A02265 46-SP...
  • Page 47: Repair Protection Agreements

    Repair Protection Agreements Reparaciones Congratulations on making a smart Felicitacfones por hacer una compra purchase. Your new Craftsman '_ product inteligente. Su nueva unidad Craftsman ® est& is designed and manufactured for years diseflada y fabricada para aflos de operaci6n of dependable operation.