Section 3: Installing The Stove; Section 3: Installation; Étape 1 Emplacement - Heat & Glo TIARA I Installer's Manual

Direct vent gas fireplace heater
Hide thumbs Also See for TIARA I:
Table of Contents

Advertisement

3
Installing the Stove
Step 1
Locating the Stove
The diagram below shows space and clearance
requirements for locating the stove within a room.
Tiara I
33 3/8 (848mm)
Tiara II
36 3/4 (933mm)
Figure 3. Stove Dimensions, Locations, and
Space Requirements
Clearance Requirements
The minimum clearance to a perpendicular wall
extending past the face of the stove is six inches
(150mm).
The back of the stove may NOT be recessed into
combustible construction.
16 1/8 (410mm)
9 7/8 (251mm)
4 5/8 (118mm)
18 1/2 (470mm)
12 1/4 (311mm)
4 (102mm)
Installation
Étape 1
Emplacement
Le schéma ci-dessous indique les dégagements et
les espaces d'isolation à prévoir pour l'installation de
l'appareil de chauffage dans une pièce.
6 (152mm)
9 (229mm)
Figure 3. Dimensions, emplacement et
dégagements à prévoir
Distances d'isolation à prévoir
La distance minimum entre l'appareil de chauffage
et un mur perpendiculaire dépassant l'avant de
l'appareil est de 150 mm (6 in.).
L'arrière de l'appareil de chauffage NE PEUT PAS
être encastré dans une construction combustible.