Electrical - Keston 50 - GC Installation And Servicing Instructions

Fan powered high efficiency condensing gas boiler
Table of Contents

Advertisement

WD50/2/1997
Chapter 2 - Boiler Connections
room containing a bath or shower, any electrical switch or appliance control, utilising
mains electricity, should be so situated that it cannot be touched by a person using the
bath or shower.
Compartment installation is permitted - such compartments must be constructed in
accordance with BS 6798.
The wall on which the boiler is mounted must be of suitable load bearing capacity and
must be non-combustible.
Important : It is not recommended to install the boiler on a studded wall or similar - it is
possible that the vibration from the fan would be amplified and transmitted to other parts
of the house.
[NB: Refer to
Section 2.8.3]
The Keston can be located virtually anywhere desired provided that all regulations are
met. Because of the boiler's compact size and venting flexibility, the installation is not
limited to a boiler room setting. Before locating the boiler near a living space consider
whether the sounds generated by the boiler will be objectionable. Sound levels from the
boiler are no greater than from any other type of high-efficiency boiler but even minimal
levels may be objectionable if located near a bedroom or in a living area.
2.4

ELECTRICAL

2.4.1
Installation & Servicing Instructions
Electrical Connections
The boiler must be connected to a 230V ~ 50Hz supply, fused at 5A. All
external controls and wiring must be suitable for mains voltage. Wiring
external tothe boiler must be in accordance with current I.E.E wiring regulations
and local regulations.
Page : 7
The Keston 50, 60 & 80 Condensing Boilers
Chimneys not used for
venting any other
appliance may be used.
Secure air & flue pipes at
chimney outlet.
Figure 2.3
Condensate drain