March 2004
6.3

Fast Test Cycle:-

Press and hold Keylock, then Start/Pause for 5 seconds
All LEDs & LCD segments except Keylock are illuminated
Press Power Button Twice
FC will show in the display
Press Start/Pause Twice
The 5 minute fast test cycle will start
Press Power
To exit
6.4

Continuous Cycle:-

Press and hold Keylock, then Start/Pause for 5 seconds
All LEDs & LCD segments except Keylock are illuminated
Press Power Button Three times
CC will show in the display
Press Start/Pause
The last cycle that had been selected prior to going into diagnostics mode will be run continuously
Press Power
To exit
6.5
Temperature & Voltage Display Mode:-
(not available on integrated models)
Start a wash cycle running
Press & hold Keylock for 4 seconds
Keylock will be activated
Press & hold Start/Pause for 8 Seconds
LCD will now alternate between °C symbol & the water temperature
Press Start/Pause
LCD will now alternate between °E symbol & the controllers rail voltage
Press & hold Keylock for 4 seconds
Keylock is deactivated
Press Power
To exit
(integrated: Heavy, Normal, Delicate, Rinse LEDs showing)
(integrated: Heavy, Normal, Rinse LEDs showing)
- 25 -