Download Print this page
Fluke Norma Star Point Features

Fluke Norma Star Point Features

Advertisement

Quick Links

Norma Star Point Adapter
 max. 500 V Phase to Phase
 High frequency range 100 kHz
 Compensated phase angle
 Basic uncertainty ± 0,2%
 Insulation 600V CAT III
 Safety input plugs
 Insulated safety output
connectors
Introduction
Norma Star Point Adapter generates a
virtual star point in 3-phase delta systems
without neutral for measuring purposes.
Applied Standards and
Regulations
Norma Star Point Adapter conforms to the European
Low Voltage Directive 2006/95/EC.
Norma Star Point Adapter is designed in accordance
with the harmonized standard
IEC 61010-1: Pollution Degree 2,
IEC 61010-2-030: 600 V CAT III
Safety of Measuring, Control and Laboratory
Equipment Part 1: General Requirements
Protection Class II according to IEC 61140
Pollution degree 2
Contacting Fluke
To contact Fluke, call one of the following
telephone numbers:
USA: 1-800-44-FLUKE (1-800-443-5853)
Canada: 1-800-36-FLUKE (1-800-363-5853)
Europe: +31 402-675-200
Japan: +81-3-6714-3114
Singapore: +65-6799-5566
Anywhere in the world: +1-425-446-5500
USA Service: 1-888-99-FLUKE (1-888-993-5853)
Or, visit Fluke's Web site at www.fluke.com.
To register your product, visit register.fluke.com

Advertisement

loading

Summary of Contents for Fluke Norma Star Point

  • Page 1 3-phase delta systems without neutral for measuring purposes. Applied Standards and Regulations Norma Star Point Adapter conforms to the European Low Voltage Directive 2006/95/EC. Norma Star Point Adapter is designed in accordance with the harmonized standard...
  • Page 2: Technical Data

    Technical Data Nominal Resistance between phases: 200k // 260pF Max. Voltage between phases: 500V Basic Uncertainty: ± 0,2% Uncertainty at 100kHz: ± 1% Measurement Category: 600V CAT III / 300V CAT IV Dimension: 195 x 125 x 57 mm Weight: 445g Protection: IP 40 Operating Temperature: –10 to +40°C Storage Temperature: -10°C to +70°C...
  • Page 3: Safety Information

    If you do not respect the safety instructions, serious injury or damage to equipment can occur. If the Norma Star Point Adapter is connected to higher voltages against earth (max. 600V CATIII) the output connections “HI” carry these high voltages!
  • Page 4: Instructions For Use

    LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for one year from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling.