1-9 CHANNEL 2:
In the delayed validity default setting the Channel 2 output will output a negative (-) signal after the
button is pressed for more than 1.5 seconds and will continue until the button is released.
The latched output selection will output a negative (-) signal as soon as the
and will continue until the button is pressed again.
The latched/reset with ignition output selection operates just like the latched output but will reset
or stop when the ignition is turned on.
The 30-second timed output selection will latch the Channel 2 output on for 30 seconds when the
remote button is pressed or until the button is pressed again within the 30 seconds.
1-10 FACTORY ALARM DISARM (FAD) WITH CHANNEL TWO ON/OFF: Any time Channel 2 is acti-
vated from the remote the factory disarm output will pulse to disarm the vehicle's factory anti-theft
device. This option can be programmed off if desired.
1-11 SECURITY FEATURES ON/OFF: When On the security features (starter kill and panic) will acti-
vate if the ignition key is turned On while the doors are locked. When Off the security features
(starter kill and panic) will not activate if the ignition key is turned On while the doors are locked.
1-12 CODE-HOPPING ON/OFF: The system features Code-Hopping as an option. To use Code-
Hopping technology, this feature must be programmed On.
1-13 CHANNEL 4: This output can be programmed to produce a validity output that will stay active
as long as the remote button assigned to that channel is pressed, a latched output, a latched output
reset with ignition, or a 30-second timed output.

menu #2

2-1 ENGINE CHECK ON/OFF: In the default setting the remote start will monitor either the vehicle's
tach wire or voltage depending on the programming of Feature 2-2. If programmed off, the vehicle
will crank for the programmed crank time (Feature 2-5) and will not verify with tach or voltage that
the vehicle is running. In the off setting, if the vehicle fails to start, the ignition can stay on for the
entire run duration. Use tach check instead of voltage check is always recommended.
2-2 TACH WIRE SENSE/VOLTAGE SENSE: If the tachometer signal wire is used, this feature must be
left in the default (tach wire connected) setting. If programmed to the voltage sense setting, the unit
will crank the starter for a preset time that can be programmed in Feature 2-5. Once the starter has
been engaged, the system will check the voltage level to verify the engine is running. The threshold
for the voltage level test can be programmed in Feature 2-6. When using voltage sense mode, con-
nection of the H3/5 WHITE tachometer input is not necessary.