13.33.6 Error reporting
The following table shows the values returned in the Status and Error Registers when specific error
conditions are encountered by a device.
Error condition
A S.M.A.R.T. FUNCTION SET command was received by
the device without the required key being loaded
into the Cylinder High and Cylinder Low registers.
A S.M.A.R.T. FUNCTION SET command was received by
the device with a subcommand value in the Features
Register that is either invalid or not supported by
this device.
A S.M.A.R.T. FUNCTION SET command subcommand other
than S.M.A.R.T. ENABLE OPERATIONS was received by
the device while the device was in a "S.M.A.R.T.
Disabled" state.
The device is unable to read its Attribute Values or
Attribute Thresholds data structure.
The device is unable to write to its Attribute
Values data structure.
Figure 128. S.M.A.R.T. Error Codes
Travelstar 48GH, 30GN & 15GN hard disk drive specifications
185
Status
Error
Register
Register
51h
04h
51h
04h
51h
04h
51h
10h or 40h
51h