Before Enable Address Offset Mode
A reserved area has been created using a non-volatile Set Max Address Command.
User Accessible Area
LBA 0
After Enable Address Offset Mode
The former reserved area is now the user accessible area. The former user accessible area is now the
reserved area.
After Set Max Address Command using the Value Returned by Read Max Address Command
Set Feature Disable Address Offset Mode, hardware or Power on Reset returns the device to Address Offset
Mode Disabled. Software reset returns the device to Address Offset Mode Disabled if Set Features Disable
Reverting to Power On Defaults has not been set.
K6602743
Rev.2
02.12.'02
Reserved Area
LBA R
User Accessible Area
(former Reserved
Area)
LBA 0
User Accessible Area
LBA 0
LBA M
Reserved Area
(former User Accessible Area)
LBA M-R
- 81 -
LBA M
LBA M