Chapter 2
Camera Installation
Connect the power and I/O cables to the GPIO terminal block
h.
Use the included L-type wrench to secure the conduit base to the mounting plate with the three included
Step 7
screws.
Remove the black cover.
Step 8
(Optional) Use mini cable with BNC connector to temporarily attach an NTSC or PAL compliant analog
Step 9
video display device to the analog video out port on the rear of the IP camera.
The mini cable with BNC adapter is included in the audio/video cables accessory kit, which you can
Note
purchase from Cisco (Cisco part number CIVS-AVCABLE).
Analog video is enabled by default to allow you to adjust the camera field of view during installation.
However, it is not supported as a normal camera feed and is automatically disabled when any of the
following camera settings are made:
The primary video stream frame rate must be set higher than 15 fps.
•
The secondary video stream must is enabled.
•
We recommend that you disable analog video after installation. To disable analog video, see the Cisco
Note
Video Surveillance 6000 Series IP Camera Configuration Guide.
OL-28492-02
1
2
3
4
5
6
7
8
Installing the IP Camera with a Vandal Resistant Enclosure
Pin
Description
1
12 VDC-
2
12 VDC+
3
24 VAC
4
24 VAC
5
DI-
6
DI+
7
DO-
8
DO+
Cisco Video Surveillance 6030 IP Camera Installation Guide
2-7