Installing the IP Camera with a Vandal Resistant Enclosure
Installing the IP Camera with a Vandal Resistant Enclosure
To install the IP camera to using a vandal resistant (VR) enclosure, perform the following steps.
Procedure
Attach the included alignment sticker to the ceiling or wall.
Step 1
Using the circle marks on the sticker, drill at least two pilot holes symmetrically on each side (four holes
Step 2
total) into the ceiling or wall. Then hammer the included wall anchors into the holes.
Step 3
Secure the mounting plate to the ceiling or wall with the four included screws.
Step 4
Do one of the following to feed the cables to the IP camera:
Perform the following steps to install and connect an RJ45 Ethernet cable (24AWG [0.51 mm] gauge
Step 5
recommended).
a.
Cisco Video Surveillance 6030 IP Camera Installation Guide
2-4
Cut out a section of the ceiling or wall that corresponds to the triangular cutout on the alignment
sticker, and feed cables through a ceiling or wall.
Use a screwdriver to remove the cutout on the side of the conduit base, connect a cable conduit, and
feed the cables through the side of the conduit base.
Drill a hole on the rubber seal plug and insert an Ethernet cable (without a connector) through the
opening.