STORAGE

• Follow cleaning instructions A-D.
• Remove the exhaust hose and window kit and repack the unit in its original
shipping box. Store unit upright in a dry place where the temperature will
remain above 35°F.
• IMPORTANT: Always store and transport the unit so as to maintain the
compressor in a upright orientation.

TECHNICAL SPECIFICATIONS

MODEL
VOLTAGE
AMPERAGE:
COOLING
HEATING
POWER CONSUMPTION:
COOLING
HEATING
COOLING CAPACITY
HEATING CAPACITY
DEHUMIDIFYING CAPACITY(30ºC, RH80%)
NOISE LEVEL (Indoor use)
AIR CIRCULATION (m
3
/h)
REFRIGERANT
REMOTE CONTROL
TIMER
DIMENSIONS (WxDxH)
NET WEIGHT
408.72012
120V~60Hz
12 Amps
10.5 Amps
1400W
1200W
12,000BTU/h
12,000BTU/h
126.8 Pints/Day (60 Liters/Day)
53 dB(A)
265 CFM maximum at high
fan speed
R410A
INCLUDED
0-24h
21.7" x 12" x 29.9"/
55cm x 30cm x 76cm
65 lbs/29.5 kg
20

TROUBLESHOOTING

If your air conditioner fails to operate, please follow these procedures prior
to contacting customer service.
DO NOT ATTEMPT TO OPEN OR REPAIR THE AIR CONDITIONER
YOURSELF. DOING SO WILL VOID THE WARRANTY AND CAUSE DAMAGE
OR PERSONAL INJURY.
PROBLEM
POSSIBLE CAUSE
Can I turn the unit on immediately
after unpacking it?
Unit does not start when pressing
Room temperature is higher
power button
than the set temperature
(heating mode).
Room temperature is lower
than the set temperature
(cooling mode).
The air conditioner does not
No electricity
come on
It is not plugged into the
outlet
The internal safety device
has tripped
The safety device on the
plug has tripped
The air conditioner works for only
There are bends or kinks in
a short time
the air exhaust hose
Something is preventing the
air from being discharged
Room is not cool enough
Windows/doors in room
are open
There are heat sources
nearby
Exhaust hose is not
connected or is blocked
Temperature setting is too
high
The air conditioner does not
Air filter blocked by dust
operate for about three minutes
The compressor control
after restarting it
prevents the unit from
being restarted until three
minutes have elapsed since
it was last turned off
Noise or vibrations
The floor is not level or the
unit is on an incline
Gurgling sound
The sound comes from
the flowing of refrigerant
inside the air conditioner
SOLUTION
No. The unit must be placed upright
for at least 12 hours after every
transport. Otherwise the compressor
may be damaged.
Lower the set temperature
Raise the set temperature
Check house circuit breaker panel
for tripped switch.
Plug into outlet
Wait 30 minutes; if problem persists,
call 1-800-469-4663 to arrange for
product inspection and repair.
Reset the safety plug
Position the air hose correctly,
keeping it as short and free of
curves as possiuble to avoid
bottlenecks.
Check and remove any obstacles
obstructing air discharge.
Close all windows/doors
Remove heat source if possible
Connect the exhaust hose and make
sure it can function properly
Decrease the set temperature
Clean the air filter
Wait. This delay is part of normal
operation
Place the unit on a flat, level surface
This is normal