COMBINATION RATINGS CONTINUED
ARI Ref. No.
Model Number
3631130
24ABC660A**30
3631427
24ABC660A**30
3631606
24ABC660A**30
3631658
24ABC660A**30
3631686
24ABC660A**30
3632218
24ABC660A**30
3631693
24ABC660A**30
3631698
24ABC660A**30
3630664
24ABC660A**30
3630715
24ABC660A**30
3630766
24ABC660A**30
3631057
24ABC660A**30
3631107
24ABC660A**30
3631135
24ABC660A**30
3631428
24ABC660A**30
3631611
24ABC660A**30
3631663
24ABC660A**30
3631691
24ABC660A**30
3632219
24ABC660A**30
3631697
24ABC660A**30
3631923
24ABC660A**30
3631719
24ABC660A**30
3631799
24ABC660A**30
3631815
24ABC660A**30
3631856
24ABC660A**30
3632308
24ABC660A**30
3631886
24ABC660A**30
3632315
24ABC660A**30
{ Tested combination
EER
Energy Efficiency Ratio
SEER — Seasonal Energy Efficiency Ratio
TDR
— Time---Delay Relay. In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance.
Use either the accessory Time---Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Carrier furnaces are equipped with TDR.
TXV
— Thermostatic Expansion Valve
UI
— User Interface
NOTES:
1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE
computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4. Do not apply with capillary tube coils as performance and reliability are affected.
Indoor Model
Furnace Model
CNPV*6124A**
58ME(B,C)120---20
CNPV*6124A**
58MV(B,C)120---20
CNPV*6124A**
58PH*090---16
CNPV*6124A**
58PH*110---20
CNPV*6124A**
58PH*135---20
CNPV*6124A**
58UVB120---20
CNPV*6124A**
58VLR120---20
CNPV*6124A**
58VMR120---20
CSPH*6012A**
58CV(A,X)110---20
CSPH*6012A**
58CV(A,X)135---22
CSPH*6012A**
58CV(A,X)155---22
CSPH*6012A**
58ME(B,C)080---16
CSPH*6012A**
58ME(B,C)100---20
CSPH*6012A**
58ME(B,C)120---20
CSPH*6012A**
58MV(B,C)120---20
CSPH*6012A**
58PH*090---16
CSPH*6012A**
58PH*110---20
CSPH*6012A**
58PH*135---20
CSPH*6012A**
58UVB120---20
CSPH*6012A**
58VLR120---20
CSPH*6012A**+TDR
FE4ANB006+UI
FV4BNB006
FV4CNB006
FX4CN(B,F)060
FX4DN(B,F)061
FY4ANB060
FY5BNB060
35
Capacity
EER
SEER
55,000
13.0
16.0
55,000
12.5
15.5
55,000
13.0
16.0
55,000
13.0
16.0
55,000
13.0
16.0
55,000
12.5
15.5
55,000
12.5
15.2
55,000
12.5
15.0
54,000
12.5
15.5
54,500
13.0
16.0
55,000
13.0
16.0
54,000
12.5
15.2
54,000
13.0
16.0
54,500
13.0
16.0
54,000
12.5
15.2
54,000
12.5
15.5
55,000
13.0
16.0
54,500
13.0
16.0
54,000
12.5
15.2
54,000
12.5
15.2
55,000
12.5
14.5
55,000
13.0
16.0
55,000
13.0
16.0
55,000
13.0
16.0
55,000
13.0
16.0
55,500
13.5
16.0
55,000
12.0
14.0
54,500
12.0
14.0