Troubleshooting - Schwinn Airdyne AD6 International model Assembly Manual

Assembly and owner's manual
Hide thumbs Also See for Airdyne AD6 International model:
Table of Contents

Advertisement

Condition/Problem
Console will not power up/
turn on/start
Speed displayed is not
accurate
Speed displayed is always
"0"/stuck in Pause mode
No speed/RPM reading
Console displays "Lbatt"
error code
Unit operates but Tele-
metric Heart Rate not
displayed
Console shuts off (enters
sleep mode) while in use
Things to Check
Batteries
Check data cable integrity
Check data cable
connections/orientation
Check console display for
damage
Display set to wrong unit
of measure. (English/
Metric)
Data cable
Speed Sensor (under
Shrouds)
Check data cable integrity
Check data cable
connections/orientation
Check Speed Sensor
Magnet position (requires
shroud removal)
Check Speed Sensor As-
sembly (requires shroud
removal)
Batteries
Chest Strap (optional)
Interference
Replace Chest Strap
Replace Console
Check data cable integrity
Check data cable
connections/orientation
Check Speed Sensor
Magnet position (requires
shroud removal)
Check Speed Sensor As-
sembly
Make sure batteries are installed correctly. If batteries are
correctly installed, replace with a set of new batteries.
All wires in cable should be intact. If any are visibly crimped or
cut, replace cable.
Make sure cable is connected securely and oriented properly.
Small latch on connector should line up and snap into place.
Check for visual sign that console display is cracked or
otherwise damaged. Replace Console if damaged.
If the above steps do not resolve the problem, contact your
local Schwinn
distributor.
®
Change display units (consult "Console Service Mode")
Make sure the data cable is connected to the back of the
Console and the main frame assembly.
Make sure the Speed Sensor Magnet and the Speed Sensor
are in place.
All wires in cable should be intact. If any are cut or crimped,
replace cable.
Be sure cable is connected securely and oriented properly.
Small latch on connector should line up and snap into place.
Magnet should be in place on pulley.
Speed Sensor Assembly should be aligned with magnet and
connected to data cable. Realign sensor if necessary. Replace
if there is any damage to the sensor or the connecting wire.
Replace batteries
Strap should be "POLAR
" compatible and uncoded. Make
®
sure strap is directly against skin and contact area is wet.
Try moving unit away from sources of interference (TV, Micro-
wave, etc).
If interference is eliminated and HR does not function, replace
strap.
If HR still does not function, replace Console.
All wires in the cable should be intact. If any are cut or crimped,
replace cable.
Be sure cable is connected securely and oriented properly.
Small latch on connector should line up and snap into
place.
Speed Sensor Magnet should be in place on pulley.
Contact your local Schwinn

TROUBLESHOOTINg

Solution
distributor.
®
25