MAINTENANCE AND TROUBLESHOOTING

Inspect and tighten all parts of the exercise bike regu-
larly. Replace any worn parts immediately.
To clean the exercise bike, use a damp cloth and a
small amount of mild soap. IMPORTANT: To avoid
damage to the console, keep liquids away from
the console and keep the console out of direct
sunlight.
CONSOLE TROUBLESHOOTING
If the console does not function properly, replace all
the batteries at the same time. See assembly step 7 on
page 8 for battery replacement instructions.
If the console does not display your heart rate when
you use the handgrip heart rate monitor, see step 5 on
page 15.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted.
To adjust the reed switch,
you must first remove the
Shield Cover (12). Using
a flat screwdriver, release
the tabs on the Shield
Cover, and then lift the
Shield Cover away from
the frame.
12
18
Next, locate the Reed Switch (46). Loosen, but do not
remove, the M4 x 16mm Screw (61).
43
61
46
44
Next, rotate the Pulley (43) until a Magnet (44) is
aligned with the Reed Switch (46). Slide the Reed
Switch slightly toward or away from the Magnet. Then,
retighten the M4 x 16mm Screw (61).
Rotate the Pulley (43) for a moment. Repeat these
actions until the console displays correct feedback.
When the reed switch is correctly adjusted, reattach
the shield cover.