Auxiliaries

Slow
Zoom: Reduces the speed at which the MIC zooms.
PTZ
Scale: Scales the MIC speed dependant on zoom position.
Wiper: Turns on or off the MIC wiper if fitted.
Washer: Activates the washer relay on the MIC-WKT card or the MIC-ALM card if
fitted in the PSU. This also moves the MIC to the stored
turns on the wiper. Once de-activated the MIC will return to its original position and
turn off the wiper.
IR /
Thermal: Dependant on the MIC this will do one of 3 things, for a Non-IR
Standard MIC the IR cut filter will come in and the image will go black and white.
For a twin IR MIC, the cut filter will come in and the lamps will turn on.
Note: If the lamps do not turn on, ensure the power supply is an IR version and
that
Auto Alarm
and
Multi Alarms
in the
For a MIC412, the video output will switch from the Sony module to the thermal
module; the controls on the
Thermal
Digital
Zoom: This will enable the MIC to continue into the digital zoom once the
optical limit has been reached. This also needs to have
under the
MIC Setup
tab.
Auto
Pan: This will start the MIC panning between left and right defined limits.
On Screen
Data: This activates the Sony modules on screen icons.
Bosch Security Systems
WashWipe
position and
MIC Setup
tab are both turned on.
tab will also now function.
Digital Zoom Enabled
Issue 1

Preset Positions

Preset positions are locations stored by the MIC in Pan, Tilt and Zoom, Focus etc,
which can be either called back manually, or returned to as part of a preset
position tour.
To learn a position move the MIC to the desired location and then either enter in
the preset number in the box available or press the
displays the desired value. Then press the
value in the input box will be cleared.
Returning to a position uses the same number entry method and then press the
Go To
instead.
The
Learn All Presets
button will set every preset position available for the given
protocol to the current position. This may take a few seconds.
AAAEN | 34
Preset Number
button until it
Learn
button to store. Once stored the